Toro Greensmaster TriFlex 3300 Manual page 111

Hide thumbs Also See for Greensmaster TriFlex 3300:
Table of Contents

Advertisement

Location
Harness
1
Main
2
Main
1
Main
2
Main
Pass
The resistance tests passed, but the voltage readings in Step 8 are still bad.
Note:
Do not go to Step 10 until after the voltage readings in Step 8 are good, and the fault
is still reporting.
Fail
One or more of the power and ground wiring tests failed. Repair or replace the worn or damaged
parts. Go to
Step 10: Swap cutting reel motors between cutting units.
All of the cutting reel motors are identical.
1.
Locate cutting reel motor 1.
Pin
Connector
P18
2
P09
4
P17
1
P09
4
Returning the Machine to Service (page 21)
Wire
Expected
Color
Reading
Black
(BK)
(48 V
Ground)
Less than
2 ohms
Black
(BK)
(48 V
Ground)
White (W)
30k to 32k
Black
ohms
(BK)
(48 V
Ground)
and follow the steps listed.
111
Connector Graphic

Advertisement

Table of Contents
loading