The Unitronics V350-35-TA24, V350-S-TA24, V350-J-TA24, V350-JS-TA24 offers the following
onboard I/Os:
12 Digital Inputs, configurable via wiring to include 2 Analog, 2 PT100/TC, and
1 HSC/Shaft-encoder Input
10 Transistor Outputs, 2 Analog Outputs
General Description
V350 OPLCs are micro-OPLCs, rugged programmable logic controllers that comprise:
On-board I/O configuration
Built-in operating panel containing a 3.5" Color Touchscreen and programmable function keys
Communications
1 built-in serial port: RS232/RS485
Optional: the user may install -
- Second RS232/RS485 port (V100-17-RS4, V100-17-RS4X)
or
- Ethernet (V100-17-ET2, V100-S-ET2),or
- Profibus Slave (V100-17-PB1) and
- CANbus (V100-17-CAN, V100-S-CAN)
Standard Kit Contents
Vision controller
I/O connectors (x2)
Battery (installed)
Programming cable + RS232 adapter
Alert Symbols and General Restrictions
This document uses the following alert symbols to highlight notices that must be observed in order
to ensure personal safety and/or prevent property damages.
Symbol
Meaning
Danger
Warning
Caution
Caution
Before using this product, the user must read and understand this document.
All examples and diagrams are intended to aid understanding, and do not guarantee operation.
Unitronics accepts no responsibility for actual use of this product based on these examples.
Please dispose of this product according to local and national standards and regulations.
Only qualified service personnel should open this device or carry out repairs.
Failure to comply with appropriate safety guidelines can cause severe injury or property damage.
Do not attempt to use this device with parameters that exceed permissible levels.
Do not connect/disconnect the device when power is on.
Unitronics
V350-35-TA24, V350-S-TA24
V350-J-TA24, V350-JS-TA24
Installation Guide
Mounting brackets (x2)
Rubber seal
2 sets of key label slides
Unitronics' Setup CD
Description
The identified danger causes physical and property damage.
The identified danger could cause physical and property damage.
Use caution.
1

Advertisement

Table of Contents
loading

Summary of Contents for Vision OPLC V350-35-TA24

  • Page 1 V350-35-TA24, V350-S-TA24 Vision™ OPLC™ V350-J-TA24, V350-JS-TA24 Installation Guide The Unitronics V350-35-TA24, V350-S-TA24, V350-J-TA24, V350-JS-TA24 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog, 2 PT100/TC, and 1 HSC/Shaft-encoder Input 10 Transistor Outputs, 2 Analog Outputs...
  • Page 2: Environmental Considerations

    V350-35-TA24, V350-J-TA24, V350-S-TA24, V350-JS-TA24 Installation Guide Environmental Considerations Do not install in areas with: excessive or conductive dust, corrosive or flammable gas, moisture or rain, excessive heat, regular impact shocks or excessive vibration, in accordance with the standards given in the product’s technical specification sheet. Do not place in water or let water leak onto the unit.
  • Page 3: Din Rail Mounting

    Vision™ OPLC™ 4. When properly mounted, the controller is squarely situated in the panel cut-out as shown in the figure to the right. DIN-rail Mounting 1. Snap the controller onto the DIN rail as shown in the figure to the right.
  • Page 4 V350-35-TA24, V350-J-TA24, V350-S-TA24, V350-JS-TA24 Installation Guide I/Os This model comprises a total of 12 inputs and 10 digital, 2 analog outputs.Input functionality can be adapted as follows: 1. All 12 inputs may be used as digital inputs. They may be wired in a group via a single jumper as either npn or pnp.
  • Page 5 Vision™ OPLC™ I/O Wiring I/O Configuration npn Input Wiring Input wiring npn (sink) HSC input wiring, npn (sink) pnp Input Wiring Input wiring pnp (source) HSC input wiring, pnp (source) Shaft-encoder Analog Input Wiring Analog input wiring, current (2/3 wire) Analog input wiring, current/voltage (4-wire) Shields should be connected at the signal’s source.
  • Page 6: Power Supply

    V350-35-TA24, V350-J-TA24, V350-S-TA24, V350-JS-TA24 Installation Guide Thermocouple Type Temp. Range Wire Color ANSI (USA) BS1843 (UK) -5 to 56mV 200 to 1820˚C +Grey +None (300 to 3276˚F) -Red -Blue -200 to 750˚C +Violet +Brown (-328 to 1382˚F) -Red -Blue -200 to 760˚C +White +Yellow (-328 to 1400˚F)
  • Page 7: Communication Port

    Vision™ OPLC™ Use separate wires to connect the functional earth line (pin 3) and the 0V line (pin 2) to the system earth ground. Install an external circuit breaker. Guard against short-circuiting in external wiring. Double-check all wiring before turning on the power supply.
  • Page 8: Opening The Controller

    V350-35-TA24, V350-J-TA24, V350-S-TA24, V350-JS-TA24 Installation Guide RS232 to RS485 Jumper Settings The figure to the right shows the jumper factory default settings. Note that in order: To change the communication setting to RS485, set both COMM jumpers to ‘485’. To change the RS485 termination, set both TERM jumpers to ‘OFF’.

This manual is also suitable for:

Oplc v350-s-ta24Oplc v350-j-ta24Oplc v350-js-ta24