ELECTRICAL

MOTOR SWITCH SETTINGS
DISCONNECT POWER BEFORE WORKING ON PUMP, MOTOR,
PRESSURE SWITCH, OR WIRING.
1/2 HP motors are dual voltage and are factory set to 115 V. 3/4 &
1 HP motors are also dual voltage, but are factory set to 230 V.
Motor terminal board (located under the motor end cover) should
look like that shown below. Use the instructions to set your
motor to match your power source.
NEVER connect a motor set to 115 V to a 230 V
power source.
PLUG TYPE VOLTAGE SELECTOR
Voltage is set to 230 V . To change to 115 V:
Figure 6: Voltage set to 230 V, Plug Type
1.
Make sure power is off.
2.
Pull the voltage change plug off of the tabs.
3.
Move the voltage change plug to the 115 V position. The plug
will now cover 2 metal tabs and the arrow on the plug will
line up with the 115 V arrow on the label (see Figure 7).
Figure 7: Voltage set to 115 V, Plug Type
P15002 (11-01-22)
4.
Attach the incoming power leads to the two outer screws on
the pressure switch as shown in Figure 6.
5.
Attach the ground wire to one of the grounding
connections, shown in Figure 6.
6.
If there are other wires, they should be capped.
7.
Reinstall the motor end and pressure switch covers.
DIAL TYPE VOLTAGE SELECTOR
Voltage is set to 230 volts . To change to 115 V:
Figure 8: Voltage set to 230 V, Dial Type
1.
Make sure power is off.
2.
Turn the dial counter-clockwise until 115 shows in the dial
window as shown in Figure 9.
Figure 9: Voltage set to 115 V, Dial Type
3.
Attach the incoming power leads to the two outer screws on
the pressure switch as shown in Figure 8.
4.
Attach the ground wire to the grounding connections as
shown in Figure 8.
5.
If there are other wires, they should be capped.
6.
Reinstall the motor end and pressure switch covers.