Troubleshooting - Graco GCI Series Instructions Manual

Table of Contents

Advertisement

Troubleshooting

Troubleshooting
Problem
Grease not reaching the dispense
point
Indicator pin not moving up
Excessive piston vent hole leakage
Excessive grease at dispense point
8
Follow Pressure Relief Procedure in the pump
instruction manual, included with your automatic
lubrication system, before checking or repairing the
injectors.
Cause
Pressure setting is too low
Blocked line
Cartridge injector is seized
Pressure setting is too low
Cartridge injector is seized
Failed dynamic seals in cartridge
injector
Output spacer is too large
Cartridge fluid bypass due to worn
out seals
Solution
Increase the pump pressure
Clear the line blockage
Replace the cartridge injector
Increase the pump pressure
Replace the cartridge injector
Replace the cartridge injector
Replace the output spacer with a
smaller output size
Replace the cartridge injector
3A9293E

Advertisement

Table of Contents
loading

Table of Contents