5 SETUP AND MAINTENANCE
5.1 FUNCTIONAL TESTING AND MAINTENANCE
The device should be tested before full operation.
For that, the correct fixing should be assured as so the cable and connections integrity and the
electrical function of the device should be checked.
Regular inspections should be performed to check the integrity of all parts described above.
ATTENTION!
The device has to be integrated into the periodic check-ups according to the
Ordinance on Industrial Safety and Health, however at least 1x/year.
5.2 AUTO-CHECK FUNCTIONS
Inputs can be actuated individually in a double channel without the necessity for simultaneity.
However, the two inputs should necessarily be deactuated for the activation of the system's
outputs.
This device adopts positive polarity to activate inputs S1 and negative polarity to activate input S2.
ATTENTION!
Therefore, they cannot be interconnected (changed to single channel input) or
the functionality of the device will be corrupted.
Setup and Maintenance
CPA-D | 5-1
5