Summary 1 ABOUT THIS DOCUMENT ............... 1-1 1.1 OBJECTIVE ....................1-1 1.2 AUTHORISED PERSONNEL ..............1-1 1.3 SYMBOLS USED IN THIS MANUAL ............1-1 1.4 APPROPRIATE USE ................1-1 1.5 EXCLUSION OF LIABILITY ..............1-1 2 DESCRIPTION ................... 2-1 2.1 DESTINATION AND USE ................. 2-1 2.2 TECHNICAL INFORMATION ..............
About this Document 1 ABOUT THIS DOCUMENT 1.1 OBJECTIVE This manual has every single information about the device and shall answer all questions involving it. Here is gathered all information about mounting, setups, connections and placement of the safety relay and its appendages. With safe operation in mind, this document ensures safety if read and followed in its fully.
Description 2 DESCRIPTION 2.1 DESTINATION AND USE The Automatic Emergency Stop Controls were developed to increase the safety level for the emergency stop system of the machine. These controls supervises the contacts of emergency buttons, sensors used in protective grids and other important devices that are vital for the system safety.
Description 2.3 SAFETY LEVELS IEC 60 204-1, ISO 13850, EN 60947-5-1, Standards EN ISO 13849-1, IEC 61508, EN 62061 PL Category Control Category PFH-Value 2.90 E-10 1/h Service Life 20 years 2-2 | CPA-D...
Installation and Connections 3 INSTALLATION AND CONNECTIONS 3.1 INSTALLATION INSTRUCTIONS The device must be set on a DIN rail by the bottom of the enclosure. Connect the back of the enclosure onto the rail by its bottom and push it down until it clicks onto the rail.
Setup and Maintenance 5 SETUP AND MAINTENANCE 5.1 FUNCTIONAL TESTING AND MAINTENANCE The device should be tested before full operation. For that, the correct fixing should be assured as so the cable and connections integrity and the electrical function of the device should be checked. Regular inspections should be performed to check the integrity of all parts described above.
Dismounting and Disposal 6 DISMOUNTING AND DISPOSAL 6.1 DISASSEMBLY This device should only be disassembled after its de-energizing. Pull the metallic latch, below the enclosure, towards you (using preferentially a screw driver) and pull the device up. 6.2 DISPOSAL As this device should be handled and carried with care, it should be disposed likewise. It should be disposed in accordance under national prescriptions and legislations.
Appendix 7 APPENDIX 7.1 START CONFIGURATION The device needs an interconnection between the reset’s inputs (Y1 and Y2) to activate the outputs. This reset button may be from a simple pushup button to a NO contact. The device cannot be used in applications which demand a manual reset. 7.2 SENSOR CONFIGURATION An example of configuration is described below Figure 7.2 on page...
Page 15
Appendix Note: Automatic start Utilization of feedback function Fuse Y1 Y2 13 23 33 41 24 V dc/ac S12 S11 14 24 34 Emergency button Figure 7.2: Example of configuration Automatic start Y1 Y2 33 41 CPA-D 24 V dc/ac 14 24 34 Gate sensor Actuator...