Before using the camera cable for inspection or switching on the LED illumination, please always remove the protective
cap at the camera head to avoid overheating damages.

Installation

Step 1
Connect the camera cable with the main unit. Plug in the connectors of main unit and control unit (camera cable)
carefully.
Please do not apply strong pressure, but you only have to pay attention to the notches inside the
connectors. Align the two connectors so that the notches fit perfectly into each
other. Make sure that the plastic
tab at 12 o'clock position inside the connector of the main unit is plugged in the matching notch (9 o'clock position) inside
the connector of the camera cable (see photos below).
Do not apply violence or excessive
force, but first insert the
two parts loosely into each other .
main unit
camera cable
Step 2
After you connected main unit and camera cables screw
the locknut directly under the connector of the main unit
and tighten it firmly by rotating it right and upwards (see
figure at right).
Step 3
Check if both parts are firmly connected and if the main unit no longer wobbles. Otherwise it will drop down if you use the
device. It is normal that the main unit can be rotated 160° to the left and right. But it must not wobble.