Download Print this page
Dantel 41095 Installation & Operation Manual

Dantel 41095 Installation & Operation Manual

Order wire control and speaker monitor panels

Advertisement

Quick Links

About this Practice:
This practice has been reissued to:
• Incorporate all addendums.
Reissued Practices: Updated and
new content can be identified by a
banner in the right margin.
Issue date: August 1998
Copyright 1998 by Dantel, Inc. • Dantel is a registered trademark of Dantel, Inc. • ISO 9001 Registered
O
RDER
S
PEAKER
HEADSET
CALL LAMP
1 2 3 4 5 6
CHANNEL SELECT

Table of Contents

Ordering Information ........................................................................... 2
General Description .............................................................................. 2
Circuit Description ............................................................................... 3
Installation ............................................................................................ 6
Operation ............................................................................................ 10
Technical Specifications ..................................................................... 11
Warranty ............................................................................................. 12
CAUTION
Install or remove modules from the shelf only when the power is off.
If you install a module in the shelf with the power on, the internal
circuitry may suffer damage and the product warranty will be void.
Remove and install circuit boards only in a static-safe environment
(use antistatic wrist straps, smocks, footwear, etc.).
Keep circuit boards in their antistatic bags when they are not in use.
Do not ship or store circuit boards near strong electrostatic, electromag-
netic, magnetic, or radioactive fields.
For more complete information on electrostatic discharge safety
precautions, refer to Bellcore
Printed in the U.S.A.
I
NSTALLATION
41095
W
C
IRE
ONTROL AND
M
ONITOR
ABC
DEF
1
2
3
GHI
JKL
MNO
4
6
5
PRS
TUV
WXY
7
8
9
OPER
#
*
0
TM
Technical Reference # TR-NWT-000870.
& O
M
PERATION
41095-0898 <90-00129>
P
ANELS
FA2
FA1
_
1
_
1
2
2
A
A
M
M
P
P
VOLUME
CONTROL
SPK 1
SPK 2
1
2
3
4
5
6
SPEAKER 2 MONITOR SELECT
ANUAL

Advertisement

loading

Summary of Contents for Dantel 41095

  • Page 1: Table Of Contents

    For more complete information on electrostatic discharge safety Issue date: August 1998 precautions, refer to Bellcore Technical Reference # TR-NWT-000870. Copyright 1998 by Dantel, Inc. • Dantel is a registered trademark of Dantel, Inc. • ISO 9001 Registered Printed in the U.S.A.
  • Page 2: Ordering Information

    Panel (41095 Panel) provides centralized monitoring facili- ties for six or twelve selective signaling order wire terminals. You can use the 41095 Panel to orginate a call or answer an incoming call on an individual order wire channel. The 41095 Panel mounts in an EIA standard 19” rack next to or near the order wire terminal.
  • Page 3: Circuit Description

    STA Select THRU 10 F THRU Fig. 2 shows the 41095 Order-Wire and Speaker Monitor Panel functional schematic. The 41095 Panel monitoring section monitors all associated order wire channels over the speaker. Incoming calls couple through transformers to operational amplifiers, and a volume control potentiometer to feed speaker amplifiers.
  • Page 4 You can use a headset instead of the handset. Fig. 3 shows the 41095 Panel channel select schematic for wiring six order wire terminals (41095-10) or twelve order wire termi- nals (41095-01).
  • Page 5 CIRCUIT DESCRIPTION . 3 - S , 41095 CHEMATIC HANNEL ELECT P104 J7 XMT R J1 XMT R XMT R J1 RCV R J7 RCV R RCV R CHANNEL 1 CHANNEL 7 J7 RCV T J1 RCV T RCV T...
  • Page 6: Installation

    Jumper pins P1-2 to P1-6 on each order wire. Refer to Table A and Fig. 5. 5. Wire to the DTSS3A terminal. Wire the 41095 Panel to the DTSS3A with modular cords or wire-wrap connections. Refer to Fig. 6. 41095-0898 <90-00129>...
  • Page 7 23" mounting AUDIBLE SIGNALING MODULE 17.00" (SHOWN WITH COVER REMOVED) TOP VIEW 41095 HEADSET 1 2 3 7 8 9 HANDSET VOLUME CONTROL SPK 1 SPK 2 CALL LAMP CIRCUIT SPEAKER 2 MONITOR SELECT CHANNEL SELECT 19.00" FRONT VIEW 41095-0898 <90-00129>...
  • Page 8 Terminal No. 2 Order-wire Terminal No. 3 Order-wire Terminal No. 4 Order-wire Terminal No. 5 Order Wire Terminal No. 6 1 2 3 4 5 6 7 8 9 10 1 1121314 151617 Wiring the 41095 signaling function 41095-0898 <90-00129>...
  • Page 9 J101 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Wiring the 41095 to the DTSS3A Using Modular Cords (Signaling Wiring not shown) 1 2 3 4 5 6 7 8 9 10...
  • Page 10: Operation

    Monitor a single channel by pressing the desired SPEAKER MONITOR CHAN SELECT push-button and turning the SPK 2 VOLUME CONTROL clockwise until you hear a sufficient level. On the 12-channel 41095 Panel (41095-01), the MONITOR SELECT push-buttons connect the following channels to the following circuits: ♦...
  • Page 11: Technical Specifications

    Operating Temperature Range 0° to 55° C. Output Power (per speaker) 1 watt Maximum Input Level -10 dBm Frequency Response 300 to 8 KHz + 1 dB @ 1 watt Input Impedance 600 ohm sourcing from low impedance 41095-0898 <90-00129>...
  • Page 12: Warranty

    To ensure expedient processing of your order, provide a purchase order number and shipping and billing information when requesting an RMA number. Also, when the units are returned to Dantel, include a descrip- tion of the failure symptoms for each unit returned. Send defective equipment to: Dantel, Inc.

This manual is also suitable for:

B13-41095-10C13-41095-01