Dantel 46018 Installation & Operation Manual

Dantel 46018 Installation & Operation Manual

Audible alarm module

Advertisement

Quick Links

About this Practice:
This practice has been reissued to:
• Incorporate the Addendum into the
practice (-00 option discontinued).
• Replace Fig. 2.
Reissued Practices: Updated and
new content can be identified by a
banner in the right margin.
Issue date: January 1998
Copyright 1998 by Dantel, Inc. • Dantel is a registered trademark of Dantel, Inc. • ISO 9001 Registered
46018 A
A
LARM

Table of Contents

Ordering Information ........................................................................... 2
General Description .............................................................................. 2
Circuit Description ............................................................................... 3
Application Information ....................................................................... 5
Installation ............................................................................................ 6
Operation .............................................................................................. 9
Technical Specifications ....................................................................... 9
Warranty ............................................................................................. 10
CAUTION
Install or remove modules from the shelf only when the power is off.
If you install a module in the shelf with the power on, the internal
circuitry may suffer damage and the product warranty will be void.
Remove and install circuit boards only in a static-safe environment
(use antistatic wrist straps, smocks, footwear, etc.).
Keep circuit boards in their antistatic bags when they are not in use.
Do not ship or store circuit boards near strong electrostatic, electromag-
netic, magnetic, or radioactive fields.
For more complete information on electrostatic discharge safety
precautions, refer to Bellcore
Printed in the U.S.A.
I
NSTALLATION
UDIBLE
M
ODULE
(AAM)
46018-01
FOUR LEVEL
AUDIBLE
ALARM
OUTPUT
EXT
LEVEL
ADJ
A11-56018-01 REV__
TM
Technical Reference # TR-NWT-000870.
& O
M
PERATION
ANUAL
46018-0198 <90-00007>

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 46018 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dantel 46018

  • Page 1: Table Of Contents

    For more complete information on electrostatic discharge safety Issue date: January 1998 precautions, refer to Bellcore Technical Reference # TR-NWT-000870. Copyright 1998 by Dantel, Inc. • Dantel is a registered trademark of Dantel, Inc. • ISO 9001 Registered Printed in the U.S.A.
  • Page 2: Ordering Information

    ORDERING INFORMATION NOTE: This section lists the different options available for this product. To order any of the avail- able options, contact Dantel Inside Sales through our toll-free number, 1-800-432-6835. OPTION NUMBER FEATURES A11-46018-01 Audible Alarm Module (AAM) GENERAL DESCRIPTION he 46018 Audible Alarm (AAM) provides an audible alarm through the application of a ground to the input.
  • Page 3: Circuit Description

    CIRCUIT DESCRIPTION ig. 1 shows the 46018 Audible Alarm functional schematic. The circuit consists of: An Oscillator The oscillator receives a ground from any one of four inputs; each of the inputs having four common pins. When grounded, a voltage comparator enables the oscillator tones.
  • Page 4 CIRCUIT DESCRIPTION . 1 - F , 46018 UNCTIONAL CHEMATIC 46018-0198 <90-00007>...
  • Page 5: Application Information

    APPLICATION INFORMATION ig. 2 shows a 460 Alarm and Control System configuration showing alarm gathering, reporting, and annunciation using the 46018 Audible Alarm Module. . 2 - 460 A 46018 A LARM AND ONTROL YSTEM LOCK IAGRAM USING UDIBLE LARM...
  • Page 6: Installation

    The strap selects the output waveform (sawtooth or square) which varies the alarm’s audio tone. The option switches select tone options. Refer to Fig. 3 and Tables A and B. . 3 - S , 46018 WITCH AND TRAP OCATIONS...
  • Page 7 3. Install the module in the proper slot in the equipment shelf. 4. Checkout To check the operation of the 46018 AA, monitor the unit in a system: Apply an alarm (ground) at each input being used and observe the front panel for proper operation.
  • Page 8 INSTALLATION . 4 - P , 46018 ESIGNATIONS -20 VDC Output External Output External Output -21 to -56 VDC Input 2 Input 1 Ground Input 4 Input 3 COMPONENT SIDE CIRCUIT SIDE OF PC BOARD OF PC BOARD 46018-0198 <90-00007>...
  • Page 9: Operation

    OPERATION . 5 - F , 46018 here are no specific operating instructions for the 46018 RONT ANEL Audible Alarm Module. The unit begins operation with application of power. 46018-01 The audible level is user-adjustable from the front panel. Refer FOUR LEVEL to Fig.
  • Page 10: Warranty

    To ensure expedient processing of your order, provide a purchase order number and shipping and billing information when requesting an RMA number. Also, when the units are returned to Dantel, include a descrip- tion of the failure symptoms for each unit returned. Send defective equipment to: Dantel, Inc.

This manual is also suitable for:

A11-46018-01

Table of Contents