REG:
When installing the device in a distributor,
clip it onto a symmetrical DIN rail (TH 35-
15). To ease connecting the device, the ter-
minal covers can be removed (see Fig. 2).
One of the terminal covers can be removed
to connect the network.
Remove the terminal covers:
Insert a suitable screwdriver
into the notch.
Fig. 2
Removing the terminal covers (REG variant)
The electrical connection of the motor
control unit is established according to the
wiring diagram on the back (see Fig. 6).
Electrical installation
An on-site overload current protection device (fuse) and a
disconnecting and isolating switch to switch off the entire
system must be provided.
The device meets the EMC directives for use in residential
and commercial areas.
Commissioning
The device is operational after the installation has been
completed and the supply voltage applied.
Maintenance
There are no parts within the device that require mainte-
nance.
Cleaning
Clean the housing with a soft, dry cloth. Do not use deter-
gents, cleaning agents, solvents, abrasive substances or
steam cleaners!
Liability
The liability for consequential damage to persons or
property is excluded if the device is used for any purpose
other than those described in these instructions. Observe
the information in the operating instructions for your sun
shading system. Liability is also excluded for damage to
the sun shading system resulting from operation under icy
conditions.
Obligations for the disposal of electrical devices
A marking with this symbol indicates the following
obligations under the scope of legal regulations:
The owner of this electrical device must dispose of it
separately from unsorted municipal waste for further
recycling.
Used batteries and accumulators that are not enclosed
in the old device, as well as lamps/bulbs that can be
removed from the old device without breaking, must be
disposed of separately.
Distributors of electrical devices and disposal compa-
nies are obliged to take back the equipment free of
charge.
The owner must take it upon themselves to delete any
personal data contained in the electrical device prior to
disposal.
2
We reserve the right to make technical modifications
Technical data
GA Kompakt
Supply 230 V AC
Operating voltage
Current consumption,
primary
Floating output
DC switching voltage per
facade
AC switching voltage per
facade
Switching capacity per fa-
cade 230 V AC/cos ϕ =0.6
Switching capacity per
facade
Control per facade
Central voltage active
Central current active
Central voltage inactive
Local voltage active
Local current active
Local voltage inactive
Run time, up/down
Enclosure
Dimensions
Degree of protection/safety class
Degree of protection
(REG/AP housing)
Safety class
Ambient conditions
Operating temperature
Storage temperature
Humidity
(not condensing)
Degree of soiling
Connection
All connections
Terminals
All terminals
Miscellaneous
Conformity
This device complies with the EMC directives for use in
residential and commercial areas.
Article number
GA Kompakt in AP hous-
ing
GA Kompakt in REG
housing
WAREMA Renkhoff SE
Hans-Wilhelm-Renkhoff-Strasse 2
D-97828 Marktheidenfeld
Min.
Typ.
Max.
Unit
198
230
253
12
14
16
24
36
V DC
230
253
700
72
8
24
36
V DC
0.2
1
1.5
–0.5
0
1.5
V DC
8
24
36
V DC
1
1.5
2
-0.5
0
1.5
V DC
3
See Fig. 3, 4
-5
20
40
-20
20
80
10
40
85
Screwed terminals
0.5 ... 2.5 mm
Available at
www.warema.de/ce
1002 743
1002 628
warema_816835_alhb_en_v4•2022-04-01
V AC
mA
V AC
VA
W
mA
mA
min
IP30
I
°C
°C
%R
H
2
2

Advertisement