o If the distance (offset) between the pole and the traffic lane is too wide, you can incline slightly the
radar in direction of the pavement/signal side.
To keep in mind:
-
The TMA-122 is not designed to detect on more than a single lane road (approaching traffic).
-
Receding traffic within the radar lobe has no effect.
-
To get the best result in terms of accuracy, the radar bracket (n°1) must be parallel to the approaching traffic
direction.
-
The presence (stationary) detection is based on tracking algorithms: the radar needs to detect an approaching
movement combined to a decreasing speed to validate the detection. Therefore, cars already parked during
the installation won't be detected.
-
The radar might be sensitive to pedestrian movement: if a pedestrian crosses the road between the vehicle and
the stop-line, it might interfere. Furthermore, if the radar lobe is partly on the pedestrian path, a pedestrian
moving or stopping within the detection area might also create a false detection status.
Protection level
Power supply
Power consumption
User output
Temperature range
Wiring & connectors
Operating frequency
Max. transmit power
Dimensions
Weight (excl. cable &
mounting support)
Icoms Detections warrants its hardware products to be free from defects in workmanship and materials, under
normal use and service, for a period of two (2) years from the date of dispatch from Icoms Detections premises,
except for the batteries for which a warranty period of six (6) months applies.
If a product does not operate as warranted during the applicable warranty period, Icoms Detections shall, at its
option, either repair the defective unit, or deliver an equivalent product or part to replace the defective item. All
products that are replaced become property of Icoms Detections.
The defective product must be returned to Icoms Detections within the applicable warranty period. The defective
product must be shipped DDP (delivered duty paid) back to Icoms Detections, wrapped in the original or similar
shipping package to ensure that it will not be damaged during transportation. It must be accompanied by
appropriate paperwork (ask first for a Return Material Authorization number) detailing the nature of the defect
experienced.
Icoms Detections shall be under no liability in respect of any defect arising from normal wear and tear, willful
damage, negligence, damage due to inappropriate packaging, abnormal working conditions, failure to follow Icoms
Detections instructions (whether oral or in writing), misuse, improper installation, alteration or repair without
Icoms Detections approval.

TECHNICAL FEATURES

TMA-122-LV
10-30 V AC, 50-60 Hz
12V-60 V DC
@12 V DC: < 1.2 W
2 inverted relay contacts – Resistive load: 30 V AC 0.3 A – 60 V DC 0.3 A
Option 250 V relay: 250 V AC - 30 V DC – 0.3 A
2 LED outputs on front face
68 x 99 x 119 mm
0,320 kg

WARRANTY

TMA-122-MV
IP 65
15-54 V AC, 50-60 Hz
21-75 V DC
-40° C to +60° C
Weipu connector
24.185 – 24.215 Ghz
< 20 dBm EIRP
68 x 99 x 205 mm
0,510 kg
TMA-122-HV
100 V –240 V AC, 50-60 Hz
@220 V AC: < 2 W
0,543 kg