Led Indicator; N Normal Operation; Hen The Self Monitoring Detects An Error; Installation Guide - icoms TMA-122 User Manual

Configuration, tune up procedure
Hide thumbs Also See for TMA-122:
Table of Contents

Advertisement

1
I

N NORMAL OPERATION

• The red LED shows the state of the relay 2.
• The green LED shows the state of the relay 1.
2
W
-
HEN THE SELF
MONITORING DETECTS AN ERROR
The two LEDs blink quickly (2 or 4 quick flashes followed by a 1 sec break, depending on the detected error):
1. Type 1 failure: Code execution and internal micro-controller state consistency. If a problem is detected, the
system is reset.
2. Type 2 failure: Micro-controller oscillator monitoring. If a problem is detected, the system enters in "fault
mode". The LEDs show a code by blinking twice followed by a 1 second pause.
3. Type 3 failure: Microwave oscillator and receiver chain. If a problem is detected, the LEDs show a code by
blinking four times followed by a 1 second pause.
The reset takes1,500 milliseconds.
1
G
ENERAL
Installation' height: min. 3.5 m - max. 4.5 m
Offset
between pole and the roadside (O):
max. 2 m
Distance
between pole and the stop-line (D):
min. 2 m
2
A
SSEMBLY AND MOUNTING
TMA-122
Bracket n°2

Figure 7: bracket elements

1. Set the appropriate parameter values with the encoders and place the sticker!

LED INDICATOR

INSTALLATION GUIDE

Bracket n°1
Pavement
9

Advertisement

Table of Contents
loading

Table of Contents