Chengdu Ebyte Electronic Technology Co., Ltd.
5.3.2 Modify baud rate
Command frame: 01 06 00 03 00 03 39 CB
Address
0x01
Response frame: 01 06 00 03 00 03 39 CB
Address
0x01
Note:
This command is used to set the baud rate of the device to 9600.
The device defaults to 9600 baud rate without verification when it leaves the factory. Users can set the baud rate and
verification method according to actual needs.
5.5.3 Modify the parity
Command frame: 01 06 00 06 00 04 09 CB
Address
0x01
Response frame: 01 06 00 06 00 04 09 CB
Address
0x01
Note:
This command is used to set the parity bit of the device to odd parity.
The final interpretation right belongs to Chengdu Ebyte Electronic Technology Co., Ltd.
Revise history
Version
1.0
1.1
Copyright ©2012–2022, Chengdu Ebyte Electronic Technology Co., Ltd.
Function code
Register start address
0x06
0x00 0x03
Function code
Register start address
0x06
0x00 0x03
Function code
Register start address
0x06
0x00 0x06
Function code
Register start address
0x06
0x00 0x06
Revise date
2022-05-05
2022-05-31
Number of
registers
0x00 0x03
Number of
registers
0x00 0x03
Number of
registers
0x00 0x04
Number of
registers
0x00 0x04
Revise instruction
Initial version
Content revision
E108-D01 User Manual
CRC check
0x39 0xCB
CRC check
0x39 0xCB
CRC check
0x09 0xCB
CRC check
0x09 0xCB
Issued by
LC
XXN
15