Haiwell PLC User Manual page 7

Classic programmable logic controller
Hide thumbs Also See for PLC:
Table of Contents

Advertisement

en.haiwell.com
Step 6: CR26H Writes value 2 to end the calibration process
27H
Low bytes of base weight of weights in channel 1, paragraph 1
28H
High bytes of base weight of weights in channel 1, paragraph 1
29H
Low bytes of base weight of weights in channel 1, paragraph 2
2AH
High bytes of base weight of weights in channel 1, paragraph 2
2BH
Low bytes of base weight of weights in channel 1, paragraph 3
2CH
High bytes of base weight of weights in channel 1, paragraph 3
2DH
Automatic peeling range of channel 1
2EH
Channel 1 Weight Upper Limit Low Bytes (32 Bit Display)
2FH
Channel 1 Weight Upper Limit High Bytes (32Bit Display)
30H~4FH
Reserve
50H
Channel 2 average weight
Channel 2 status code:
bit0:no-load(zero point weight)
bit1:exceed the weight upper limit
51H
bit2:stability of measurement value
bit3~15:reserved
52H
Channel 2 Real-time weight
Channel 2 uses 32-bit display flags:
53H
0: 16-bit weight display
1: 32-bit weight display
Channel 2 Real-time Weight 32 Bit Value:
54H~55H
54H: 32-bit low byte
55H: 32-bit high byte
The average weight of channel 2 is 32 bits:
56H~57H
56H: 32-bit low byte
57H:32-bit high byte
58H
Channel 2 Skin Weight Low Bytes
59H
Channel 2 Skin Weight High Bytes
Channel 2 Control Setting
Bit 0: Reservation
5AH
Bit 1: Gross/Net Weight Display, 0-Gross Weight, 1-Net Weight
Bit2-15: Reservation
Channel 2 sampling frequency 0-7.5Hz,1-15Hz,2-30Hz,
5BH
3-60Hz,4-120Hz,5-240Hz,6-480Hz,7-960Hz
Reserved
5CH-5DH
5EH
Channel 2 average number of times
5FH
Channel 2 filter ratio
60H
Channel 2 standstill checking times
Channel 2 standtill checking range
61H
Channel 2 zero tracking intensity
62H
0 :close zero tracking function
others: show zero tracking intensity(absolute value)
Channel 2 zero-point detection range
63H
Channel 2 weight upper limit
Set the upper limit value of weight, when measurement value is
64H
over the set value will record error code
Channel 2 Skin Weight Read (Settings)
When 16-bit display, read the current weight value (50H) as the
65H
weight value of the leather weight and store it at 58H.
When 32-bit display, read CR56H and CR57H as skin weight Z
value and store them at 58H and 59H.
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R
R
R
R
R/W32
R
R/W
R/W
R/W
R/W
R
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
7 / 24
Haiwell PLC -- Load Cell Module User Manual
2000
0
0
0
0
0
0
32767
32767
0
0
16 bits only use 58H, 32
bits use 58H 59H.
0
Switch the current
display weight to wool
Weight or net weight,
0
used in calculation the
value of 58H and 59H as
tare weight
3
range:0~7
10
range:1~100
2
range:0~5
5
range:0~500
range:0~10000
2
vaule,range :
Abolute
0
0~200
vaule,range :
Abolute
10
0~10000
32767
0: no operation
1: Read the weight value
0
as the tare weight and
store it at 58H 59H.
Others: Invalid

Advertisement

Table of Contents
loading

This manual is also suitable for:

H01wgH02wg

Table of Contents