Gross Weight And Net Weight - Haiwell PLC User Manual

Classic programmable logic controller
Hide thumbs Also See for PLC:
Table of Contents

Advertisement

en.haiwell.com

8. Gross Weight and Net Weight

1. When the value of 25H is written to 1 and the weight value is 16-bit display, the current 16-bit weight value (10H) is read as the
weight value of the leather weight, and the weight value is read as the weight value of the leather weight; when stored in 18H and
the weight value is 32-bit display, the current 32-bit weight value (16H 17H) is read as the weight value of the leather weight, and
stored in 18H and 19H.
2, 18H, 19H store the skin weight value.
3. Enable control settings. It is controlled by Bit1 bit of 1AH. Bit1 = 0 - Gross weight, Bit1 = 1 - net weight. Switching the current
display weight to gross or net weight, the calculation uses the value of 18H (16 bits)/18H19H (32 bits) as the tare weight.
Write 1 to 25
Value is written
to 18H as tare
Haiwell PLC - Load Cell Module Application Example
IAH Bit1=0
IAH Bit1=1
16 /
24
Current gross weight, gross
weight = real weight
Current net weight, net weight =
real weight - gross weight