14. Press the upper and lower housing covers together until the plug is closed. In order
to ensure that the wires in the plug contact properly, press the plug in the middle by
means of pliers after inserting the wires.
15. Turn the locking mechanism with your hand as far as possible in the direction of the
arrow.
16. Insert a screwdriver (2.5 mm) into the slit in the locking mechanism and turn it as far
as the limit stop.
17. The plug is correctly locked when the opening of the locking mechanism is at the
side and the side edges are flush with the plug.
26
IE FC RJ45 Plug 4x2 CAT 6A
A5E34280610-AD, 01/2023