TIMER OPERATION

11 TIMER OPERATION
The unit controller must be set to the correct date and time
before using the timer function.
The timer function allows the selection of simple and scheduled
timers, as shown in the figures below:
11.5.1 Setting of Simple timer
The following parameters can be adjusted:
Frequency (Never / Once / Everyday / Weekend / Work day)
Starting Time: From 00:00 to 24:00
Setting Temperature: From 30ºC to 75ºC
Stopping time: From 00:00 to 24:00
26
PMML0544 rev.4 - 02/2023
11.5.2 Setting of Schedule timer
Pressing the OK key with "Timer Configuration" being selected
displays the detailed schedule screen. The active schedule
timers are shown in a weekly calendar.
Up to five timer events can be defined for each weekday, and
these can be used for turning the DHW heating operation on
or off, or to change the setting temperature for the DHW tank.
Pressing the OK key with one of the weekdays being selected
in the weekly calendar screen displays the detailed schedule
for the weekday. The following parameters can be adjusted for
each program within the day:
From: Starting time (the selected Status remains valid until
the time shown between brackets in the "To" column)
Status: (On / Off)
Setting: Setting temperature for the DHW tank (From 30ºC
to 75ºC)
Pressing the "Menu" button during the edition of the timer events
for a given weekday displays a menu to copy the daily pattern to
other weekdays or to suppress the selected timer event.