1. BEFORE INSTALLATION

When unpacking the indoor unit or moving the unit after
unpacked, hold the hanger brackets (4 places) and do not
apply force to other parts (particularly refrigerant piping,
drain piping and resin parts).
• Make sure to check in advance that the refrigerant to be
used for installation work is R410A.
The air conditioner will not operate properly without the
correct refrigerant.
• For installation of the outdoor unit and additional refriger-
ant charge, refer to the installation manual attached to the
outdoor unit.
• Do not throw away the accessories until the installation
work is completed.
(1) Measure the unit with packaging to ensure the unit
can be carried safely while still packaged.
(2) Determine the route to carry the unit into the room.
(3) Do not unpack the unit until it is carried to the installa-
tion location.
Where unpacking is unavoidable, use a sling of soft
material or protective plates together with a rope when
lifting, to avoid damage or scratches to the indoor unit.
• After the indoor unit is carried into the room, to avoid the
indoor unit from getting damaged, take measures to protect
the indoor unit with packing materials until the installation
begins.
• Have the customer actually operate the air conditioner
while looking at the operation manual.
Instruct the customer how to operate the air conditioner
(particularly cleaning of the air filter, operation pro cedures,
and temperature adjustment).
• For selection of installation location, use the installation
pattern combined packing material paper as reference.
• Do not use the air conditioner where in the salty atmo-
sphere such as coastal areas, vehicles, vessels or the
voltage fluctuation is frequent such as factories.
• Take off static electricity from the body when carrying out
wiring and the control box cover is removed.
The electric parts may be damaged.
1-1 ACCESSORIES
Check if the following accessories are attached to the
indoor unit.
(1) Drain
(2) Metal
Name
hose
clamp
Quantity
1 pc.
1 pc.
Shape
(5) Installation
(6) Screw
Name
pattern paper
(M4)
Quantity
1 sheet
4 pcs.
Shape
1
(3) Washer
for hanger
(4) Clamp
bracket
8 pcs.
7 pcs.
(7) Washer
Joint insulating
fixing plate
material
4 pcs.
1 each
(8) For gas
piping
(9) For liquid
piping
Name
Sealing material
Quantity
1 each
(10) Large
(12) Medium-2
Shape
(11) Medium-1
(15) Installation
(16) Insulation
Name
guide
tube
Quantity
1 sheet
1 pc.
Shape
• Joint insulating material (8) and (9) are for field piping that
is insulated to a thickness of 3/8 in. (10 mm) or less. If the
field piping is insulated to a thickness of more than 3/8 in.
(10 mm), instead of using joint insulating material (8) and
(9), use insulating material and clamps (both field supply)
that are suitable for the field piping, and be sure to carry out
insulation according to the procedure in this manual.
If not insulated, water leakage may be caused by conden-
sation.
• Screws for fixing the panel are attached to the decoration
panel.
1-2 OPTIONAL ACCESSORIES
• This indoor unit separately requires a decoration panel and
remote controllers.
• Confirm if a decoration panel shown in the Table 1 is pre-
pared and meets your model.
(Refer to the installation manual attached to the decoration
panel for how to install.)
Table 1
MODEL NAME (FCQ-AAVJU)
18 · 24 · 30 · 36 · 42 · 48
• Install the remote controller to the place where the cus-
tomer has given consent.
Refer to the catalog for the applicable model.
(Refer to the installation manual attached to the remote
controller for how to install.)
1 sheet
1 pc.
(13) Small
(14)
Conduit mounting
plate
(Miscellaneous)
• Operation
1 pc.
Manual
• Installation
Manual
(17)
• Warranty
Optional decoration panel
BYCQ54EEFU, BYCQ54EEGFU
Color : Fresh white
English