AirKing LEDAK100D Operating Manual

AirKing LEDAK100D Operating Manual

Exhaust fan with light
Hide thumbs Also See for LEDAK100D:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

IMPORTANT INSTRUCTIONS -
Models: LEDAK100D, LED100DH
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock and
WARNING:
ELECTRIC SHOCK AND INJURY TO PERSON,
OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer. If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service
panel and lock the service disconnecting means to prevent power
from being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
WARNING:
ELECTRIC SHOCK AND INJURY TO PERSON,
OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
b) Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to prevent
back drafting. Follow the heating equipment manufacturer's guideline
and safety standards such as those published by the National Fire
Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local
code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
CAUTION:
DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS AND VAPORS.
A210952014 Rev. Q 1-23
OPERATING MANUAL
INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
injury to person, including the following:
TO REDUCE THE RISK OF FIRE,
TO REDUCE THE RISK OF FIRE,
FOR GENERAL VENTILATING USE ONLY.
SAVE THESE INSTRUCTIONS
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f) To avoid motor bearing damage and noisy and/or unbalanced impellers,
keep drywall spray, construction dust, etc. off power unit.
WARNING:
OPERATION DO NOT POWER FAN UNTIL ALL CONSTRUCTION HAS
BEEN COMPLETED. THE FAN WILL DRAW IN AIRBORNE DUST THAT COULD
IMPAIR OPERATION AND REDUCE THE LIFE OF THE MOTOR. USAGE OF
FAN DURING CONSTRUCTION PROCESS WILL VOID ALL WARRANTIES.
g) Read all instructions before installing or using exhaust fan.
h) If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI (Ground
Fault Circuit Interrupter) – protected branch circuit.
i)
Do not install in a ceiling with thermal insulation value greater than R40.
WARNING:
WARNING:
OUTSIDE OF THE BUILDING HAS A STRONG EFFECT ON THE
AIR FLOW, NOISE AND ENERGY USE OF THE FAN. USE THE SHORTEST,
STRAIGHTEST DUCT ROUTING POSSIBLE FOR BEST PERFORMANCE,
AND AVOID INSTALLING THE FAN WITH SMALLER DUCTS THAN
RECOMMENDED. INSULATION AROUND THE DUCTS CAN REDUCE
ENERGY LOSS AND INHIBIT MOLD GROWTH. FANS INSTALLED WITH
EXISTING DUCTS MAY NOT ACHIEVE THEIR RATED AIRFLOW.
www.airkinglimited.com
Exhaust Fan with Light
IF FAN IS INTENDED FOR CONTINUOUS
WARNING:
TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK, DO NOT USE THIS FAN WITH
ANY SOLID-STATE SPEED CONTROL DEVICE.
DO NOT USE IN KITCHENS.
THE DUCTING FROM THIS FAN TO THE
1 of 8

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LEDAK100D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AirKing LEDAK100D

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Models: LEDAK100D, LED100DH Exhaust Fan with Light READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Existing Construction

    INSTALLATION INSTRUCTIONS Roof Cap* (with built-in CAUTION: Insulation* damper) MAKE SURE POWER IS SWITCHED OFF AT SERVICE (place around and PANEL BEFORE STARTING INSTALLATION. over Fan Housing SECTION 1 Preparing the Exhaust Fan Power Cable* Keep duct Fan Housing Unpack fan from the carton and confirm that all pieces are present. In addition to the exhaust runs short fan you should have: 1 - Grill...
  • Page 3 Intermittent Ventilation: For two speed fans wired for intermittent ventilation with a standard Install the grill (with reflector) by duplex toggle switch (not included), connect the White wires of the fan to the White (Neutral) squeezing the two ends of the springs wire from the power source.
  • Page 4: Troubleshooting Guide

    HEATER COMPONENTS ARE NOT AVAILABLE TO CONSUMERS FOR INSTALLATION OR REPLACEMENT. Qty. Description Replacement Part # Mounting Rails 5S1299002 Mounting Channel 5S1202122 Collar Assembly 5S1299111 Wire Cover Assembly - LEDAK100D 5S1202662 Wire Cover Assembly - LED100DH 5S1202663 Blower Assembly 5S2202401 Light Assembly 5S1202801 Outlet Gasket 5S1202043...
  • Page 5: Instructions Générales De Sécurité

    INSTRUCTIONS IMPORTANTES – MANUEL D’OPÉRATION Ventilateur combiner, comprend Modèles: LEDAK100D, LED100DH lumière et ventilation LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ.
  • Page 6 INSTRUCTIONS D’INSTALLATION Assurez-vous que les joints des conduits et les pénétrations extérieures sont scellés avec du mastic ou tout autre matériau similaire pour créer un passage d’air étanche afin de minimiser la perte ou le gain de chaleur et réduire le risque de condensation. Placez / enveloppez l’isolant ATTENTION : VOUS ASSURER QUE L’ALIMENTATION autour du conduit et /...
  • Page 7 Ventilation intermittente : Pour les ventilateurs à deux vitesses, raccordés pour uneventilation Installez le réflecteur sur la intermittente avec un interrupteur à bascule duplex standard (non inclus). Connectez les fils grille en plaçant les fentes blancs du ventilateur au fil blanc (neutre) de la source d’alimentation. Connectez le fil de sur le côté...
  • Page 8: Guide De Dépannage

    Description remplacement Traverses de Montage 5S1299002 Canal de Montage 5S1202122 Assemblée de collier 5S1299111 Assemblée du compartiment du fil - LEDAK100D 5S1202662 Assemblée du compartiment du fil - LED100DH 5S1202663 Assemblée de la Soufflante 5S2202401 Assemblement de lumière 5S1202801 Joint - Extérieur...

This manual is also suitable for:

Led100dh

Table of Contents