Installation Instructions
Place the unit in the required location and mark the position of the holes in the unit.
Depending on the material of the surface the unit is being attached to, use appropriate fixings
to secure the unit down through the holes in the brackets.
To sink the fryer into a work surface first cut a hole in the surface (approx. 525mm x 491mm)
When deciding where to position the fryer keep in mind that the exterior surfaces of the unit
can get very hot when the unit is in operation. Also make sure the user is still able to get
access to the controls and drain valve.
Undo the screws in the back of the unit and attach the long fixing bracket. The unit when
sunken will be supported on the bracket on the back and the lip at the front.
GAS CONNECTION
The gas connection is 3/8" B.S.P.T. on the right-hand side underneath the front of the fryer.
The supply pipe must not be less than 3/8, an easily accessible isolation cock should be fitted
in the pipework as close as possible to the fryer. An approved flex may be used in conjunction
with a straining cable.
The parts protected by the manufacturer or agent, should not be adjusted by the installer.
Gas hoses used to connect the appliance to the gas supply must be of the correct
specification for the gas and pressure of the appliance. The gas hose must comply with the
national requirements in force, and be CE marked, of a metal braided construction suitable
for commercial catering equipment. The hoses should be periodically examined and
replaced as necessary
The tube or hose shall be
fitted such that there are no sharp bends or torsional strain which may cause damage or
failure of the tube or hose, especially near the end fittings. Torsional strain can be
prevented using internal unions, swivel joints, etc. The bend radius should not exceed that
stated by the Manufacturer. The hose should not touch the ground and should be no longer
than 1.5m long.
A manual valve should be positioned upstream of the tube or hose unless the connection
fitting incorporates a self-sealing quick release coupling.