Sony HCD-LX20i Service Manual page 14

Hide thumbs Also See for HCD-LX20i:
Table of Contents

Advertisement

HCD-LX20i
FM TUNE LEVEL CHECK
signal
generator
Procedure:
1. Turn on the set.
2. Input the following signal from signal generator to FM antenna
input directly.
Carrier frequency : A = 87.5 MHz, B = 98 MHz, C = 108 MHz
Deviation
: 75 kHz
Modulation
: 1 kHz
ANT input
: 35 dBu (EMF)
Note: Use 75 ohm coaxial cable to connect signal generator and the set.
You cannot use video cable for checking.
Use signal generator whose output impedance is 75 ohm.
3. Set to FM tuner function and tune A, B and C signals.
4. Confi rm "TUNED" is lit on the display for A, B and C sig-
nals.
When the selected station signal is received in good condition,
"TUNED" is displayed.
CD SECTION
Note:
1. CD Block is basically constructed to operate without adjustment.
2. Use YEDS-18 disc (Part No. 3-702-101-01) unless otherwise indicat-
ed.
3. Use an oscilloscope with more than 10 MΩ impedance.
4. Clean the object lens by an applicator with neutral detergent when the
signal level is low than specifi ed value with the following checks.
5. Check the focus bias check when optical pick-up block is replaced.
FOCUS BIAS CHECK
CD board
TP122 (RFEQO)
TP124 (VC)
Procedure:
1. Connect oscilloscope to TP122 (RFEQO) and TP124 (VC) on
the CD board.
2. Press the [
] button to turn the power on.
?/1
3. Press the [FUNCTION +] button to select CD function.
4. Set the disc (YEDS-18) and press the [
back.
5. Confi rm that oscilloscope waveform is as shown in the fi gure
below. (eye pattern)
A good eye pattern means that the diamond shape (◊) in the
center of the waveform can be clearly distinguished.
14
set
oscilloscope
(DC range)
+
] button to play-
7
VOLT/DIV: 200 mV
TIME/DIV: 500 ns
level:
1.2 ± 0.3 Vp-p
Checking Location:
– CD Board (Conductor Side) –
TP124 (VC)
TP122
(RFEQ)
IC101

Advertisement

Table of Contents
loading

Table of Contents