Signalling Icons; Alarms; Alarms Silencing - Electrolux ecostore Premium User Manual

Vertical refrigerators
Hide thumbs Also See for ecostore Premium:
Table of Contents

Advertisement

The continuous cycle ends:
– when the button is pressed (the message cce=end
appears);
– when the minimum foreseen temperature is reached;
– when the maximum duration (time 1h) is reached;
– when the instrument is switched off.
• Set button
.
Press for more than 1 second to display and/or set the
setpoint. To increase or decrease the values use the
buttons
. To confirm the new value, press the Set
button
.
• Defrost button
IMPORTANT
Do not use mechanical devices or other means
to speed up the defrost process, unless recom-
mended by the manufacturer.
Do not damage the circuit.
The appliance has an automatic defrost function. A manual
defrost cycle can be started by keeping the button pressed
for at least 5 seconds (the display shows the message dFb ).
This function is signalled by lighting up of the defrost icon
. Defrost is with forced ventilation only for refrigerated
models with compartment set point higher than or equal to
"+2".
Defrost can be stopped manually by pressing the button for
a few seconds (the display shows the message dFE).
Defrost cannot be activated in the continuous cycle
programming phase. If the continuous cycle is activated
and the button is pressed, defrost will be carried out at the
end.
• Programme selection button
It is used in the HISTORY function (see the following
paragraph). Pressing this button also brings up the
Technical Menu, which cannot be modified.
• History button
Records the temperature every 24 hours from activation, for
a total of 62 saves.
Records high/low temperature alarms. The first press of the
button
brings up the list of daily recorded values (t00=
current day; t01, t02, t03, etc.=recording days going back).
Use the buttons
previous days.
Press the Set button
temperature of that period; to return to the list of stored
values press the button
Press the button
for a few seconds to exit the History
function. At least 24 hours must pass after installation of the
appliance before the first temperature can be recorded.
Keeping the button
the previous recordings.
• Light Button
Present in all full door and glass door freezer models and glass
door refrigerated models, its purpose is to switch on the inside
light.
G.3

Signalling icons

The digital thermostat has the following signalling ICONS:
12
to display the temperatures of
to display the recorded
.
pressed for a few seconds resets
lit up
This icon indicates compressor
activation.
lit up
This icon indicates the manual defrost
function in progress.
lit up
This icon indicates activation of com-
partment fans (if present).
lit up
This icon indicates activation of auxiliary
users (if present).
lit up
This icon indicates that a service alarm
has occurred during appliance
operation.
lit up
This icon indicates that the History
function is ON.
G.4

Alarms

• Compartment high temperature alarm
This icon lights up and an audible alarm sounds when the
compartment temperature exceeds the set maximum value.
The alarm ceases when the temperature returns to the Set
Point. A timer, which counts the alarm duration time until it is
silenced, is also activated. Pressing the History button
displays the code HI and then in sequence, pressing the
button
the number of hours since the alarm occurred.
To deactivate the icon, briefly press on it.
• Compartment low temperature alarm
This icon lights up and an audible alarm is activated when
the compartment temperature exceeds the set minimum
value. The alarm ceases when the temperature returns to
the Set Point. A timer, which counts the alarm duration time
until it is silenced, is also activated. Pressing the History
button displays the code LO and then in sequence, pressing
the button
, the number of days since the alarm
occurred. To deactivate the icon, briefly press on it.
• Door open alarm
The icon lights up when the door is opened. After the max.
door opening time the icon stays on fixed and the buzzer is
activated. The alarm ceases when the door is closed.
• Service Alarm
The message is signalled by lighting up of the icon.
Signalling also occurs with the respective code appearing
on the display and the activation of an audible alarm (see
section I.2 Troubleshooting).
G.4.1

Alarms silencing

Alarms are silenced by pressing on the lit icon. The value
indicated on the display is also automatically reset.

Advertisement

Table of Contents
loading

Table of Contents