Replacing an AC Power Supply

Step 2
Remove the fan module that you are replacing as follows:
a) On the fan module that you are removing, unscrew the two captive screws on the front of the fan module until each
screw is free of the chassis.
b) Holding the handle, pull the module out of the chassis and set it on an antistatic surface or in a antistatic bag.
Caution
Step 3
Install the replacement fan module as follows:
a) Hold the fan module with two hands. One hand holding its handle, and one hand supporting the weight of the fan
module. Align the back of the fan module (the side with the electrical connectors) to the open fan slot in the chassis.
b) Slide the fan module into the slot until it clicks in place.
c) Tighten the fan module captive screws.
d) Verify that the Status (STS) LED turns on and becomes green.
Replacing an AC Power Supply
You can replace an AC power supply during operations so long as there is another power supply installed and
operating during the replacement. The switch requires two power supplies for operations, so you can hot swap
the redundant power supply during operations. If there are only two power supplies installed in the chassis,
you can replace one by installing the new power supply in the open power supply slot before removing the
other power supply. The module number can be found on the chassis.
Note
Before you begin
• Verify that you have an ESD wrist strap or other device to prevent ESD damage to the components that
• Verify that you have an antistatic surface or bag for placing the power supply module that you remove
• Verify that the replacement power supply module has the correct direction of airflow (it has the same
Step 1
Attach an ESD wrist strap or other ESD device to your body and an earth ground to prevent ESD damage.
You can attach the ESD device to any earth ground or grounded object, such as a grounded rack or ground connection
on a chassis.
Step 2
Remove the power supply as follows:
a) Pull the power cord out from the power receptacle on the power supply to be removed and verify that the OK LED
turns off.
Cisco Nexus 9408 NX-OS Mode Switch Hardware Installation Guide
30
Do not touch the electrical connectors on the back side of the module and prevent anything else from
coming into contact with and damaging the connectors.
This switch supports port-side intake power supplies only (NXA-PAC-2KW-PI)
you touch.
from the chassis.
coloring as the other fan and power supply modules in the same chassis). Otherwise the switch can
overheat and shut down.
Replacing Modules