Warnings

 1. 
To avoid the risk of electric shock or burns, always con-
nect the safety (or earth) ground before making any other 
connections.
 2. 
To reduce the risk of fire, electrical shock, or physical 
injury, it is strongly recommended to fuse the voltage 
measurement inputs. Be sure to locate fuses as close to 
the source as possible.
 3. 
Replace fuse with the same type and rating to provide pro-
tection against risk of fire and shock hazards.
 4. 
In the event of repeated failure, do NOT replace the fuse 
again as repeated failure indicates a defective condition 
that will NOT clear by replacing the fuse.
 5. 
Only qualified electrical personnel familiar with the con-
struction and operation of this equipment and the hazards 
involved should install, adjust, operate, or service this 
equipment.
 6. 
Read and understand this manual and other applicable 
manuals in their entirety before proceeding. Failure to 
observe this precaution could result in severe bodily injury 
or loss of life.
 7. 
WARNING - Battery may explode if mistreated.   D o not 
recharge, disassemble, or dispose of     i n fire.
 8. 
WARNING - EXPLOSION HAZARD - Batteries must only 
be changed in an area known to be     n on-hazardous.
 9. 
WARNING - Do not disconnect while circuit is live unless 
are is know to be non-hazardous. 
 

FCC Compliance

This device complies with Part 15 of the FCC Rules. Operation is 
subject to the following
two conditions:
 1. 
This device may not cause harmful interference.
 2. 
This device must accept any interference received, includ-
ing interference that may cause undesired operation. 
 
 

Technical Support

North America
1 (317) 916-4274
(877) 665-5666
www.hornerautomation.com
techsppt@heapg.com
 
Europe
+353 (21) 4321-266
www.hornerautomation.eu
technical.support@horner-apg.com
 
 
 
SAFETY & MAINTENANCE

Precautions

All applicable codes and standards need to be followed in the 
installation of this product. Adhere to the following safety pre-
cautions whenever any type of connection is made to the module:
 
 
Page 9
 1. 
Connect the safety (earth) ground on the power connector 
first before making any
 2. 
other connections.
 3. 
When connecting to the electric circuits or pulse-initiating 
equipment, open their
 4. 
related breakers.
 5. 
Do NOT make connection to live power lines.
 6. 
Make connections to the module first; then connect to the 
circuit to be monitored.
 7. 
Route power wires in a safe manner in accordance with 
good practice and local codes.
 8. 
Wear proper personal protective equipment including 
safety glasses and insulated         g loves when making con-
nections to power circuits.
 9. 
Ensure hands, shoes, and floor are dry before making any 
connection to a power line.
 10. 
Make sure the unit is turned OFF before making con-
nection to terminals.
 11. 
Make sure all circuits are de-energized before making con-
nections.
 12. 
Before each use, inspect all cables for breaks or cracks in 
the insulation. Replace
 13. 
immediately if defective.
 14. 
Use copper conductors in Field Wiring only, 60/75˚C.
 15. 
Use caution when connecting controllers to PCs via serial 
or USB. PCs, especially         l aptops,may use "floating power 
supplies" that are ungrounded.   T his could cause a       d am-
aging voltage potential between the laptop and controller.  
Ensure the controller       a nd laptop are grounded for max-
imum protection. Consider using a USB isolator due to      
voltage potential differences as a preventative measure.