INSTRUCTIONS FOR USE ® VISATRON oil mist detector plus plus VN301 /VN301 Version: Version 2.0 Document No.: Part number 180072 The original instructions for use are written in German. Any translations are based on the original instructions for use.
Page 2
The reproduction, translation, microfilming and the storage and processing of these instructions, including in part, is only allowed with the consent of Schaller Automation Industrielle Automationstechnik GmbH & Co. KG. Any infringement shall attract damages and may have consequences under criminal law.
VERSION HISTORY AND CHANGE NOTES Version Change Date Author Revised entire content against the standard, restructured the 09 December sections, plus new layout with revised formatting, based on the J. Wahl 2022 existing Version 1.5. Added further sections and topics. Table 1: Version history and change notes...
OVERVIEW OF CONTENTS Table of contents Information about the instructions for use ................8 Validity of the instructions for use ....................8 Use and purpose of the instructions for use ................8 Document storage ........................8 Symbols in these instructions for use ..................8 Applicable documents and regulations ..................
Page 5
TABLE OF CONTENTS ® plus plus 4.2.1 Function of the VISATRON VN301 / VN301 Ex oil mist detection system ..... 30 4.2.2 Device variants .......................... 30 4.2.3 Function and variants of the sensor unit ................... 31 4.2.4 Central unit ..........................33 4.2.5 Hybrid cable ..........................
Page 6
/ VN301 Ex sensor unit ..............107 9.3.3 Replacing the hybrid cable ...................... 107 Repair by Schaller Automation ....................108 Taking out of service and disassembly ................... 108 Starting up for again ........................ 108 Error diagnosis and troubleshooting .................. 109 10.1 Behaviour of the oil mist detection system in the event of a fault ...........
Page 7
TABLE OF CONTENTS Spare parts for VN301plus/VN301plus Ex ................115 13.1 Spare parts list ........................115 Accessories for VN301plus/VN301plus Ex ................. 120 List of figures ........................121 List of tables .......................... 123 Glossary ..........................124 EC Declaration of Conformity ....................125 Appendix ..........................
1 Information about the instructions for use 1.1 Validity of the instructions for use These instructions for use apply to the products: ® • plus VISATRON VN301 ® • plus VISATRON VN301 hereafter referred to as the “device”. 1.2 Use and purpose of the instructions for use The instructions for use are intended for: •...
Page 9
Numbered steps: Required action Result of the sequence of actions • Symbol for a list 1. Points of the list Reference to a section or figure Display text Additional information and instructions Environmental and energy-saving tips Different warning symbols are used for warnings. Please see the descriptions and instructions in the .
INFORMATION ABOUT THE INSTRUCTIONS FOR USE 1.5 Applicable documents and regulations Further documents apply in conjunction with these instructions for use. For added components, follow the instructions supplied for those components. ( Section 19 Appendix When using the device and for all service work, also follow: •...
IEC 60079-0 (2017) and IEC 60079-28 (2015) 1.9 Liability for defects The terms in the order confirmation from Schaller Automation Industrielle Automationstechnik GmbH & Co. KG or the terms agreed in the contract apply. Claims for personal injury and damage are excluded if they are due to one or more of the following causes: •...
This document has been prepared to the best of our knowledge and belief. It represents the technical version of the device as delivered. Schaller Automation Industrielle Automationstechnik GmbH & Co. KG reserves the right to amend and revise this document, if necessary. The products supplied by Schaller Automation are production devices with long service life, developed and produced according to the current state of the art.
• EP2615269B1 For all questions and activities arising in connection with the above patent, please contact SCHALLER Automation in advance: SCHALLER Automation (Headquarters) Industrielle Automationstechnik GmbH & Co. KG Industriering 14...
SAFETY INSTRUCTIONS 2 Safety instructions These instructions for use contain safety instructions. 2.1 Safety devices and guards These instructions for use contain instructions for your safety. The following basic safety instructions are instructions that always apply in order to operate the machine safely and keep the machine in a safe condition.
Page 15
SAFETY INSTRUCTIONS CAUTION Potential risk of minor injury. Indicates a low-risk hazard that, if not avoided, may result in minor or moderate injury. NOTICE Potential damage to the device or the surroundings. Indicates a potential hazard, with the aim of preventing damage. Instructions for use ...
SAFETY INSTRUCTIONS 2.3 Information, warning and mandatory signs that are used The following symbols and signs according to DIN EN ISO 7010 and DIN 4844-2 are used in these instructions for use: Symbol Description General warning sign Warning; electricity Warning; explosive atmosphere (Atex) Warning;...
SAFETY INSTRUCTIONS Symbol Description Refer to instruction manual/booklet Note: Important information! Note: A qualified electrician is required for installation! Note: Action required! Table 3: Information, warning and mandatory signs 2.4 Basic safety instructions The basic safety instructions are instructions that always apply in order to operate the machine safely and keep the device in a safe condition.
Page 18
SAFETY INSTRUCTIONS DANGER Malfunction Operating the device with a malfunction creates a risk of death and may cause environmental damage and/or damage to the device. The device must be taken out of operation immediately in the event of a malfunction.
Page 19
SAFETY INSTRUCTIONS DANGER Electrical hazards Electrical damage to the device from welding work on the engine as a result of overvoltage. ® Before starting work, disconnect the VISATRON plus plus VN301 /VN301 central unit from the power supply. You may only assemble, install and remove the device when the engine is switched off.
Section 3.1 Marking and type description Only use tools suitable for potentially explosive atmospheres. Note that modifications are not allowed without prior approval from SCHALLER AUTOMATION. Make sure that damaged products are not installed or operated in the potentially explosive atmosphere.
IDENTIFICATION Type plate, VISATRON ® VN301 plus Fig.: 1 : central unit 1: VISATRON ® VN301 plus central unit 2: Type plate (attached to left side) The following information is provided on the type plate: Type plate, VISATRON ® VN301 plus Fig.: 2 : central unit...
IDENTIFICATION 3.3.2 Type plate on the VISATRON ® VN301 plus sensor unit The serial number (type plate) is attached to the outside on the end cover of the sensor unit. End cover with serial number on the VISATRON ® VN301 plus Fig.: 3 : sensor unit...
IDENTIFICATION 3.4 Technical data 3.4.1 Mechanical and electrical interfaces Section 6.4.3 (Figure 34) Electrical and pneumatic installation of the central unit plus plus VN301 / VN301 Ex sensor unit Max. dimensions (L x W x H) approx. 205 x 92 (max. 167) x 70 mm Weight Sensor unit: 0.85 kg...
IDENTIFICATION 3.4.2 Environmental conditions Section 6.4.3 (Figure 34) Electrical and pneumatic installation of the central unit Environmental conditions Operating temperature +5°C to +70°C Storage temperature -25°C to +50°C Max. approval-compliant vibrations for the device 5 Hz to 25 Hz: 1.6 mm (max.
PRODUCT OVERVIEW 4 Product overview 4.1 Component overview and dimensions Component overview, VISATRON ® VN301 plus Fig.: 5 : plus 1: VN301 central unit plus 2: Sensor unit VN301 3: Hybrid cable Component overview, VISATRON ® VN301 plus Fig.: 6 : plus 1: VN301 central unit...
Page 27
PRODUCT OVERVIEW plus plus Fig.: 7 : Mechanical dimensions of VN301 / VN301 Ex sensor unit plus 1: Sensor unit VN301 , vertical plus Sensor unit VN301 Ex, vertical plus 2: Sensor unit VN301 , horizontal plus Sensor unit VN301 Ex, horizontal Instructions for use ...
PRODUCT OVERVIEW plus Fig.: 8 : Mechanical dimensions of VN301 central unit Instructions for use VISATRON® oil mist detector VN301plus/VN301plus Ex Part number 180072 Version 2.0...
PRODUCT OVERVIEW plus Fig.: 9 : Mechanical dimensions of VN301 central unit; version with water separator Instructions for use VISATRON® oil mist detector VN301plus/VN301plus Ex Part number 180072 Version 2.0...
During normal engine operation, the oil mist detector draws in any existing oil mist. The oil mist detector has been developed by SCHALLER AUTOMATION according to the guidelines of the International Association of Classification Societies (IACS) IACS UR M10.
PRODUCT OVERVIEW 4.2.3 Function and variants of the sensor unit The function of the sensor unit has been described in detail above. Section 4.2.1 Function of the VISATRON® VN301plus / VN301plus E Features of the sensor unit ® • plus plus All VISATRON...
PRODUCT OVERVIEW plus VN301 sensor unit, horizontal connection plus Fig.: 11 : Sensor unit VN301 , horizontal connection plus VN301 Ex sensor unit, vertical connection plus Fig.: 12 : Sensor unit VN301 , vertical connection Instructions for use VISATRON® oil mist detector VN301plus/VN301plus Ex Part number 180072 ...
PRODUCT OVERVIEW plus VN301 Ex sensor unit, horizontal connection plus Fig.: 13 : Sensor unit VN301 , horizontal connection 4.2.4 Central unit ® plus plus The central unit of the VISATRON VN301 / VN301 Ex provides the user with the following functions: •...
PRODUCT OVERVIEW plus Fig.: 15 : VN301 central unit, version with water separator 1: Water separator The central unit is designed to withstand extreme conditions such as vibrations or high temperatures at the engine. All important information is available at a glance. Up to 10 sensor units can be connected to the central unit, and up to 20 sensor units as master- slave version.
PRODUCT OVERVIEW 4.2.5 Hybrid cable ® ® plus The connection between the VISATRON VN301 central unit and the VISATRON ® plus plus VN301 / VISATRON VN301 Ex sensor unit is established using a hybrid cable [1], as shown in the figure below. At the front end of the cable (on the sensor side), there is a hybrid plug [2], which contains the electrical connection and a compressed air connection, and is connected to the sensor unit.
PRODUCT OVERVIEW 4.2.7 Setting the oil mist sensitivity The VISATRON® VN301plus/VN301plus Ex system determines the oil mist concentration using an optical measurement at the applicable sensor units. The values are calculated as the percentage for “opacity”. 100% opacity means that no light penetrates through the oil mist sample.
PRODUCT OVERVIEW 4.4 Foreseeable misuse NOTICE Applications and methods not referred to or described in these instructions are not allowed! ® plus plus Installing the VISATRON VN301 / VN301 Ex without using the sensor intake manifolds is not allowed. ® plus plus Installation and maintenance of the VISATRON...
PRODUCT OVERVIEW plus 4.5.1.1 Fault indicators, VN301 central unit As per the figure above, system faults are displayed using the following indicators or are identified specifically using the keys [6] and [7]: 2: System status, central unit 5: Status, sensor units (Nos. 1-10) System faults are described in detail in Section 10 “Troubleshooting”.
TRANSPORT AND STORAGE 5 Transport and storage 5.1 Unpacking and items included in delivery ® plus plus When you receive the VISATRON VN301 / VN301 Ex oil mist detection system, check the whole delivery to ensure that it contains all the components. Schaller Automation provides a detailed parts list for you to use for this purpose.
TRANSPORT AND STORAGE Storage temperature range -25°C to max. 50°C Relative humidity [RH] < 85% and avoiding condensation Table 8: Storage conditions before starting up CAUTION Incorrect storage can damage the device. Keep the storage period for the device to a minimum. ...
ASSEMBLY AND INSTALLATION 6 Assembly and installation WARNING Failure to comply with the safety instructions may result in major damage to property or the environment and in serious injury or death. Familiarise yourself with the basic safety instructions before starting assembly. ...
ASSEMBLY AND INSTALLATION DANGER Electrical hazards ® Before connecting the electrical supply lines to the VISATRON plus VN301 plus VN301 Ex central unit, the central unit must first be disconnected from the power supply. ® Before starting work, disconnect the VISATRON VN301 plus /VN301...
ASSEMBLY AND INSTALLATION If the oil mist detection system is operated in Ex-protected areas, the relevant safety instructions must be observed. Section 2.4.1 Safety instructions for potentially explosive atmospheres 6.3 Assembling the system components CAUTION Safe and correct assembly of the device ...
6.3.1 Class-compliant assembly and installation according to IACS Unified Requirement UR M10 The oil mist detector has been developed and approved by SCHALLER AUTOMATION in accordance with the requirements of the International Association of Classification Societies (IACS) IACS UR M10 (class-compliant assembly and installation) and M67 (sensitivity of the oil mist detector and determination of the oil mist concentration).
ASSEMBLY AND INSTALLATION 6.3.2.1 Assembly procedure for the engine wall screw fitting plus plus Fig.: 20 : Engine wall screw fitting, VN301 VN301 sensor unit 1: Intake manifold 2: Union nut (G3/4" or M27x1.5) 1: Intake manifold 2: Screw-in thread, engine wall: G3/4" or M27x1.5 3: Engine wall Instructions for use ...
Page 46
ASSEMBLY AND INSTALLATION Adjust the horizontal position of 1: Intake manifold the engine wall screw fitting! 1: Intake manifold 2: Union nut Instructions for use VISATRON® oil mist detector VN301plus/VN301plus Ex Part number 180072 Version 2.0...
ASSEMBLY AND INSTALLATION 6.3.3 Central unit WARNING Impairment of function and operation of the device The oil mist detection system must not be painted, varnished or otherwise altered. DANGER Risk of injury from overhead loads A suitable means of transport must be used for assembly and for transport to the assembly site.
ASSEMBLY AND INSTALLATION 6.3.4 Remote Indicator II for remote monitoring (optional) ® plus plus The VISATRON VN301 / VN301 Ex system can be connected to the Remote Indicator II for remote monitoring to monitor the oil mist concentration and the system status from a safe location according to IACS UR M10.
ASSEMBLY AND INSTALLATION DANGER Mechanical hazards There is a risk of serious injury, including death, due to explosion in the crankcase as a result of incorrect assembly or installation. Before starting the engine, the hybrid plug of the hybrid cable must be connected to the sensor unit and locked.
ASSEMBLY AND INSTALLATION 6.4.1.1 Operating mode 1: One central unit in use (when using max. 10 sensor units) Fig.: 25 : Operating mode 1 “Master”, VN301 plus central unit 6.4.1.2 Operating mode 2: Two central units in use (for use with 11 ore more sensor units) Fig.: 26 : Operating mode 2 “Master/Slave”, VN301 plus...
ASSEMBLY AND INSTALLATION 6.4.2 Electrical and pneumatic connection of the sensor unit ® plus The electrical and pneumatic connection between the VISATRON VN301 central unit and sensor unit is established using a hybrid cable [1] as shown in the figure below. At the front end of the cable (on the sensor side), there is a hybrid plug [2], which contains the electrical connection and a compressed air connection, and is connected to the sensor unit.
Page 53
ASSEMBLY AND INSTALLATION Compressed air connection Compressed air connection Position: Top 1: Hybrid plug plus 2: Sensor unit VN301 1: Hybrid plug plus plus 2: VN301 / VN301 Ex sensor unit Instructions for use VISATRON® oil mist detector VN301plus/VN301plus Ex Part number 180072 ...
ASSEMBLY AND INSTALLATION plus plus Fig.: 28 : Assembling the hybrid cable on the VN301 / VN301 Ex sensor unit (steps 1-4) 6.4.3 Electrical and pneumatic installation of the central unit All the electrical terminal connections and the pneumatic connections are on the connection board in the central unit, as shown in the figure below;...
ASSEMBLY AND INSTALLATION The electrical and pneumatic connection is established as per the installation steps below: plus Fig.: 30 : VN301 central unit; remove the aluminium cover strips on the cover plus 1: VN301 central unit 2: Aluminium cover strip plus Fig.: 31 : VN301 central unit;...
ASSEMBLY AND INSTALLATION plus Fig.: 32 : Open the VN301 central unit plus 1: Bottom half of housing, VN301 central unit plus 2: Cover, VN301 central unit plus Fig.: 33 : VN301 central unit, electrical and pneumatic connection (see Fig. 34 for key) Instructions for use ...
ASSEMBLY AND INSTALLATION plus Fig.: 34 : VN301 central unit, view of cable connection panel 1: Terminal block for relay contacts (M25) 5: Compressed air distributor unit 2: Terminal block for power supply (M20) 6: USB port plus 3: Terminal block for sensor connection (M20) 7: Connection for cover of VN301 central unit 4: Terminal block for communication (M16)
ASSEMBLY AND INSTALLATION plus Fig.: 36 : VN301 central unit; establish power supply (connect contacts) plus Fig.: 37 : VN301 central unit; tighten the EMC cable gland Instructions for use VISATRON® oil mist detector VN301plus/VN301plus Ex Part number 180072 Version 2.0...
ASSEMBLY AND INSTALLATION plus Fig.: 38 : VN301 central unit; establish alarm plus Fig.: 39 : VN301 central unit; establish alarm (connect contacts) Instructions for use VISATRON® oil mist detector VN301plus/VN301plus Ex Part number 180072 Version 2.0...
ASSEMBLY AND INSTALLATION plus Fig.: 40 : VN301 central unit; tighten the EMC cable gland plus Fig.: 41 : VN301 central unit sensor connection (electrical/ pneumatic, sensors 1-10) Instructions for use VISATRON® oil mist detector VN301plus/VN301plus Ex Part number 180072 Version 2.0...
ASSEMBLY AND INSTALLATION plus Fig.: 42 : VN301 central unit sensor connection (connect contacts, sensors 1-10) plus Fig.: 43 : VN301 central unit; tighten the EMC cable gland plus Fig.: 44 : VN301 central unit; establish compressed air connection (sensors 1-10) 5: Compressed air distributor unit Instructions for use ...
ASSEMBLY AND INSTALLATION plus 6.4.3.1 Configuration of the wire break resistors on the VN301 central unit Section 6.4.3 Electrical and pneumatic installation of the central unit As shown in Figure 29, the standard configuration of the wire break resistors as delivered is 33 k.
Page 63
ASSEMBLY AND INSTALLATION 3: Wire break resistors, NO1, NO2 Instructions for use VISATRON® oil mist detector VN301plus/VN301plus Ex Part number 180072 Version 2.0...
ASSEMBLY AND INSTALLATION plus Fig.: 46 : VN301 central unit: Swap out wire break resistors (steps 1-3) Instructions for use VISATRON® oil mist detector VN301plus/VN301plus Ex Part number 180072 Version 2.0...
ASSEMBLY AND INSTALLATION plus 6.4.3.2 Configuration of the wiring bridges on the VN301 central unit Section 6.4.3 Electrical and pneumatic installation of the central unit 4 sensors plus Fig.: 47 : VN301 central unit: Configuration of the wiring bridges; 4 sensors 1: Wiring bridges 5 sensors ...
ASSEMBLY AND INSTALLATION 10 sensors plus Fig.: 53 : VN301 central unit: Configuration of the wiring bridges; 10 sensors 6.4.4 Electrical connection of the Remote Indicator II (optional) Section 6.4.3 Electrical and pneumatic installation of the central unit ® plus plus The VISATRON...
ASSEMBLY AND INSTALLATION plus Fig.: 55 : VN301 central unit; connect contacts with Remote Indicator II (optional) 4: Assign sensor connection plus Fig.: 56 : VN301 central unit; tighten the EMC cable gland Fig.: 57 : Remote Indicator II, connect contacts (optional) 4: Assign sensor connection Instructions for use ...
ASSEMBLY AND INSTALLATION plus 6.4.5 Locking the VN301 central unit after completing the electrical installation Section 6.4.3 Electrical and pneumatic installation of the central unit After the electrical installation, the central unit is closed again as per the figure below. NOTICE Remove cable ties ...
ASSEMBLY AND INSTALLATION plus 6.4.6 Connection earth to the housing of the VN301 central unit (optional) Section 2.4 Basic safety instructions DANGER Electrical hazards Before connecting the housing earthing to the protective cover of the ® plus VISATRON VN301 central unit, the unit must first be disconnected from the power supply.
ASSEMBLY AND INSTALLATION 6.5 Starting up for the first time WARNING Risk of oil mist explosion Engine protection not guaranteed! The oil mist detector may only be started up after all the components have been completely attached To establish protection of the engine, start up the oil mist detector for the first time with the engine stopped.
ASSEMBLY AND INSTALLATION 6.5.1 Checklist for starting up for the first time If the assembly ( ) and the installation ( Section 6.3 Assembling the system components Section ) of the oil mist detection system have been completed successfully, 6.4 Electrical installation we recommend work through the following checklist before starting up for the first time: ...
ASSEMBLY AND INSTALLATION 6.5.2 Connecting the power supply The power supply has been made available in advance by the operator and installed according to Section 6.4.3. Section 6.4.3 Electrical and pneumatic installation of the central unit 1. Switch on the power supply for the oil mist detector. ...
ASSEMBLY AND INSTALLATION plus 6.5.3 Setting the supply pressure on the pressure regulator of the VN301 central unit The supply pressure to be set on the central unit is 2.5 bar. It is set as follows: plus Fig.: 61 : VN301 central unit: Setting the supply pressure 1: Oil mist alarm confirmation button 4: Last installed sensor...
Page 75
ASSEMBLY AND INSTALLATION If the supply pressure of 2.5 bar is not achieved, the 50% OMC [ LED flashes, as in the figure below. In this example, the supply pressure is only 2 bar and therefore has to be adjusted. Flashing ...
ASSEMBLY AND INSTALLATION plus Fig.: 62 : VN301 central unit: Adjusting the pressure regulator unit 1: Pressure regulator unit 2: Adjusting cap plus 6.5.4 Setting the sensor sensitivities on the VN301 central unit NOTICE ® plus Setting the sensor sensitivity on the VISATRON VN301 central unit ...
ASSEMBLY AND INSTALLATION plus Fig.: 63 : VN301 central unit: Setting the sensor sensitivity 1: Oil mist alarm confirmation button 4: Sensitivity indicator 2: Sensor units 5: Sensitivity of the sensor, with the highest OMC 3: Sensor status, with the highest OMC 6: OMC for displayed sensor ...
ASSEMBLY AND INSTALLATION If the oil mist detection system is operated in Ex-protected areas, the relevant safety instructions must be observed. Section 2.4.1 Safety instructions for potentially explosive atmospheres Once the steps in Sections 6.5.1 to 6.5.5 have been successfully completed, you can start the function test.
Page 79
ASSEMBLY AND INSTALLATION NOTICE ® plus Starting up for the first time, VISATRON VN301 central unit In the figure above, the alarm was triggered by sensor 4 (flashing red LED). The above steps apply in the same way for future function tests ...
MANUFACTURER SETTINGS 7 Manufacturer settings ® plus 7.1 Adjusting the parameters on the VISATRON VN301 central unit ® plus plus The VISATRON VN301 / VN301 Ex oil mist detection system has two available alarm thresholds. The main alarm threshold can be adjusted using the software and the USB port on the central unit as shown in the figure below.
MANUFACTURER SETTINGS DANGER You may only adjust the parameters of the central unit with the engine switched off. The compressed air supply to the oil mist detection system must also be switched off first. ® Before starting to adjust parameters, the housing of the VISATRON plus plus VN301...
MANUFACTURER SETTINGS The parameters are entered using the parameter list below: Parameter set Input values Number of VN301plus central units 1 or 2 Number of sensors for the central unit 1 to 10 Oil mist alarm threshold Sensitivity setting 1 0.7 mg/l Oil mist concentration Sensitivity setting 2 0.8 mg/l Oil mist concentration...
OPERATION AND USE 8 Operation and use This section describes how to operate the product. This section covers all the operating modes available on the product, as well as how to restart the product after a system failure, and also warns of hazardous situations that may arise during operation. WARNING Risk of oil mist explosion Failure to comply with the safety instructions may result in major damage to property...
OPERATION AND USE The oil mist detection system is functioning and ready for operation when the checklist has been completed successfully. For further information, please see Section 10 of these instructions. Section 10 Error diagnosis and troubleshooting 8.2 Operation under correct conditions plus The operating temperature of the VN301 EX (...
OPERATION AND USE Fig.: 68 : “Sensor Ready” status indicator on the VN301 plus plus / VN301 Ex sensor unit 4: “System Ready” status indicator (central unit) 1: Sensor units 2: “Sensor Ready” key (central unit) 5: “Sensor sensitivity” status indicator 3: “Sensor Ready”...
OPERATION AND USE The LED check is carried out as follows: plus Fig.: 69 : VN301 central unit: LED check (light test) 1: Oil mist alarm confirmation button 1. Press the oil mist alarm confirmation button on the central unit. [ ...
OPERATION AND USE 8.7 “Oil mist pre-alarm” status indicator When a high relative oil mist concentration is reached for at least one sensor, the LED bar indicator comes on. [ At a relative oil mist concentration of 70%, the pre-alarm relay is activated and the pre- alarm is triggered.
OPERATION AND USE NOTICE Action in the event of an oil mist alarm The sensor that first triggered the alarm is indicated by a flashing red LED (where damage has occurred). The oil mist alarm message must be confirmed by pressing the oil mist alarm ®...
OPERATION AND USE central unit: “Alarm” status indicator at 100% OMC (example) plus Fig.: 72 : VN301 8.9 Confirming an oil mist alarm DANGER Risk of death There is a risk of serious injury, including death, due to explosion in the crankcase as a result of incorrect installation.
OPERATION AND USE concentrations in the crankcase, or as soon as the concentration is below the alarm limit displayed (<70%). 1. The oil mist alarm message must be confirmed by pressing the oil mist alarm ® plus confirmation button [ ] on the VISATRON VN301 central unit.
OPERATION AND USE The figures below show the situation with reduced oil mist concentration (50%) before (Figure 70) and after (Figure 71) confirming the oil mist alarm by pressing the confirmation button. central unit: “Alarm” status indicator at 50% OMC (example) plus Fig.: 74 : VN301 1: Oil mist alarm confirmation button...
MAINTENANCE AND REPAIR 9 Maintenance and repair WARNING Warning – risk of oil mist explosion during maintenance work Safe operation is conditional on no explosive atmosphere escaping into the engine room. An explosive atmosphere that escapes can cause a risk of explosion.
WARNING Risk of serious injury or death from oil mist explosion during maintenance work Only use original spare parts from Schaller Automation for maintenance and repair work! All the maintenance work is described in the following sections. 9.1.1 Maintenance cycles for reliable operation ®...
Page 94
MAINTENANCE AND REPAIR Description Interval quarterly or after 2,000 operating hours (whichever occurs first) Hours Or months Check the supply pressure setting on the central unit: ▪ Supply pressure < 2.25 bar ➔ Adjust supply pressure 6.5.3 ▪ Supply pressure between 2.25 bar and 2.75 bar ➔...
MAINTENANCE AND REPAIR Inspection of the whole system Key to maintenance measures: X - Work that must be carried out by trained on-board personnel or by Schaller Service S - Work that may only be carried out by authorised and certified Schaller Service technicians Table 11: Maintenance cycles Instructions for use ...
MAINTENANCE AND REPAIR 9.1.2 Cleaning the measuring track area on the sensor unit (4,000 hrs.) NOTICE Cleaning and care of system components plus For cleaning system components of the VN301 oil mist detection system, the following optional products are recommended or supplied by the manufacturer: ...
Page 97
MAINTENANCE AND REPAIR When the above indicator is displayed for the first time, the sensor has a degree of contamination on the sensor measuring track area of approx. 80%. Experience has shown that there is sufficient time for intensive cleaning of the sensor before it fails completely (when the upper contamination limit (100%) is reached).
Page 98
MAINTENANCE AND REPAIR Instructions for use VISATRON® oil mist detector VN301plus/VN301plus Ex Part number 180072 Version 2.0...
MAINTENANCE AND REPAIR plus plus Fig.: 78 : Disassembly and cleaning the VN301 / VN301 Ex sensor unit (steps 1-5) 1: Holding bracket 3: M5 fixing screws (captive) 2: Sensor 4: Allen key, 4.0 mm 5: Cleaning buds from the cleaning kit 6: Cleaning kit After cleaning the sensor has been completed successfully, reassembly is carried out in reverse order as follows:...
MAINTENANCE AND REPAIR plus plus Fig.: 79 : Reassembly after cleaning the VN301 / VN301 Ex sensor unit (steps 1-6) Instructions for use VISATRON® oil mist detector VN301plus/VN301plus Ex Part number 180072 Version 2.0...
4,000 operating hours at the latest. The air filter element (366717) is part of the Schaller maintenance kit (155003) and can also be ordered separately from Schaller Automation if required. NOTICE Maintenance work on the oil mist detection system ...
Page 102
MAINTENANCE AND REPAIR The air filter element is replaced according to the following steps: plus 1: VN301 central unit 3: Plastic disc 2: Pressure regulator unit 1. Note on step 1: First unscrew the air filter cover [ ]. Then pull the air filter cover down.
MAINTENANCE AND REPAIR 3: Plastic disc 4: Air filter element NEW! No. 2; screw in hand-tight = 2.5 bar Fig.: 82 : Replacing the air filter element on the pressure regulator unit (steps 1-8) plus 1: VN301 central unit 2: Pressure regulator unit NOTICE Check supply pressure on the oil mist detection system ...
MAINTENANCE AND REPAIR 9.1.4 Function test of the sensor units using smoke tube (8,000 hrs.) plus plus To ensure reliable operation of the VN301 / VN301 Ex sensor units, a function test with a smoke tube mist test must be carried out annually or after 8,000 operating hours at the latest.
Page 105
MAINTENANCE AND REPAIR 1: Sensor 3: Allen key, 5.0 mm 2: “Test mist inlet” screw plug 1: Sensor 3: Smoke tube with hand pump 2: Quick-release coupling Instructions for use VISATRON® oil mist detector VN301plus/VN301plus Ex Part number 180072 Version 2.0...
MAINTENANCE AND REPAIR 1: Sensor 3: Red LED flashes when function test is successful 2: Smoke tube with hand pump Fig.: 84 : Function test with smoke tube (mist test, steps 1-4) After a successful function test, the sensor is returned to its initial state. To do this, repeat steps 1-2 in reverse order.
MAINTENANCE AND REPAIR 9.2 Inspection of the oil mist detection system (16,000 hrs. or after 24 months) To ensure that the device is in proper working condition, defined maintenance and inspection work must be carried out by authorised and instructed specialist personnel. In this case, an inspection by a Schaller service partner is required after 16,000 ...
MAINTENANCE AND REPAIR 9.4 Repair by Schaller Automation If you oil mist detection system is defective or malfunctions, please contact Schaller Automation or an authorised service partner immediately. See Section 12 ( in these instructions for suitable partners or go to Section 12 Contact) https://schaller-automation.com/en/partners/.
ERROR DIAGNOSIS AND TROUBLESHOOTING 10 Error diagnosis and troubleshooting WARNING Risk of oil mist explosion Failure to comply with the safety instructions may result in major damage to property or the environment and in serious injury or death. Familiarise yourself with the basic safety instructions for working with the oil ...
In the event of a sensor defect, the operator must correct the defect as quickly as possible. The easiest way to do this is to replace the faulty sensor unit. Schaller Automation generally recommends that the operator keeps up to two spare sensor units in storage at all times.
ERROR DIAGNOSIS AND TROUBLESHOOTING 10.2 Troubleshooting The displayed errors can be corrected by the customer or alternatively by an authorised Schaller service partner. In this case, contact service at Schaller Automation Industrielle Automationstechnik GmbH & Co KG. Section 12 Contact The error codes (on the display on the Remote Indicator II) and how to correct them are listed below in order.
ERROR DIAGNOSIS AND TROUBLESHOOTING Code/ Indicator/ Solution fault possible causes Green LED on the Section 10.1.1 applicable sensor Section 6.3.2, Section 6.4.2 09/ “Sensor and on the central electronics” unit is flashing at temperature regular intervals/ measurement is defective ▪ Sensor is not working 1.
This product must not be disposed of as residential waste. It is therefore marked with the symbol on the left. Schaller Automation takes back this product free of charge. Information about this is available from the national sales organisations and Schaller Automation.
Using other parts may exclude liability for the consequences. Only use original spare parts from Schaller Automation! 13.1 Spare parts list Fig.: 85 : Overview of the positions of spare parts for the VISATRON ® VN301...
SPARE PARTS FOR VN301PLUS/VN301PLUS EX Fig.: 86 : Overview of the positions of spare parts for the VISATRON ® VN301 plus sensor unit plus plus 1: VN301 and VN301 Ex sensor unit (153050, 4: Service kit plug screw G1/4 (273138) 153060, 153070, 153080) 5: Service kit O-ring (273137) 2: Service kit O-ring (273136)
Page 117
SPARE PARTS FOR VN301PLUS/VN301PLUS EX Part Number Discription plus Pressure reducer VN301 complete 273102 273114 Filter cartridge pressure reducing valve Water separator with filter- element 273118 273119 Filter cartridge for water separator plus Central unit VN301 REPLACEMENT • Without steel cover •...
Page 118
SPARE PARTS FOR VN301PLUS/VN301PLUS EX Part Number Discription plus Sensor VN301 Ex horizontal REPLACEMENT: • Sensor packed in an individual shipping box • manual on cd 153060 plus Sensor VN301 vertikal REPLACEMENT: • Sensor packed in an individual shipping box •...
SPARE PARTS FOR VN301PLUS/VN301PLUS EX Part Number Discription – 4m plus Hybrid cable VN301 273204 – 6m plus Hybrid cable VN301 273206 – 8m plus Hybrid cable VN301 273208 – 10m plus Hybrid cable VN301 273210 – 15m plus Hybrid cable VN301 273215 –...
Using unapproved accessories may affect the safety of the installation. Original accessories are necessary for the device to operate correctly and are designed for your safety. Using other parts may exclude liability for the consequences. Only use original accessories from Schaller Automation! Part Number Discription List...
LIST OF FIGURES 15 List of figures ® plus Fig.: 1 : Type plate, VISATRON VN301 central unit ............... 22 Fig.: 2 : Type plate, VISATRON ® VN301 plus central unit ............... 22 ® plus Fig.: 3 : End cover with serial number on the VISATRON VN301 sensor unit .......
Page 122
LIST OF FIGURES plus Fig.: 50 : VN301 central unit: Configuration of the wiring bridges; 7 sensors ......66 plus Fig.: 51 : VN301 central unit: Configuration of the wiring bridges; 8 sensors ......66 plus Fig.: 52 : VN301 central unit: Configuration of the wiring bridges;...
LIST OF TABLES 16 List of tables Table 1: Version history and change notes ..................3 Table 2: Variables and units of measurement that are used ............13 Table 3: Information, warning and mandatory signs ..............17 Table 4: Mechanical and electrical interfaces ................24 Table 5: Ambient conditions and physical characteristics .............
GLOSSARY 17 Glossary Term Description Oil mist detection system, designed to protect large engines plus VN301 (gas, diesel and dual fuel) Provides the functionality of the oil mist detection system and Central unit is used to parameterise measured variables Design suck in and detect the oil mist atmosphere from the Sensor unit crankcase Electrical and pneumatic connection between the VISATRON®...
EC DECLARATION OF CONFORMITY 18 EC Declaration of Conformity EC Declaration of Conformity We, the manufacturer: SCHALLER AUTOMATION Industrielle Automationstechnik GmbH & Co. KG Industriering 14 66440 Blieskastel Germany Phone: +49 6842 5080 Fax: +49 6842 508260 declare on our sole responsibility that the product:...
Page 126
EC DECLARATION OF CONFORMITY EC Declaration of Conformity We, the manufacturer: SCHALLER AUTOMATION Industrielle Automationstechnik GmbH & Co. KG Industriering 14 66440 Blieskastel Germany Phone: +49 6842 5080 Fax: +49 6842 508260 declare on our sole responsibility that the product:...
Ex sensor unit Why is the sensor unit faulty? If your sensor unit is defective or malfunctions, please contact Schaller Automation or one of our authorised service partners immediately. Please fill in the following form in full and send it to us immediately together with the defective sensor unit.
Page 128
APPENDIX Condition of the sensor unit ☐ ☐ Sensor unit mechanically damaged Not functioning when operated ☐ ☐ Is suction at the sensor unit is working correctly? ☐ ☐ Is the condition of the hybrid cable OK? ☐ ☐ Is the condition of the hybrid plug OK? ☐...
Page 129
APPENDIX If yes, please check as follows: ☐ ☐ Is there no compressed air available? If there is, is there enough compressed air available? ☐ ☐ (compared to neighbouring sensors) Is the green LED on the relevant sensor flashing ☐ ☐...
Why is the central unit faulty? If your central unit is defective or malfunctions, please contact Schaller Automation or one of our authorised service partners immediately. Please fill in the following form in full and send it to us immediately together with the defective central unit (complete or just the bottom half or the cover with display).
Page 131
APPENDIX Please enter your data for product identification: Serial number (Label on left side of housing) Central unit installed on: ☐ ☐ Main machine Auxiliary machine/power unit Engine manufacturer:______________________________ Engine type:_____________________________________ Condition of the central unit ☐ ☐ Central unit mechanically damaged ☐...