  • Page 1 Version 1.1, 09/2020 VISATRON VN93 Complement information to operating manual V2.5 11/2015 Maintenance procedures VISATRON VN93...
  • Page 2: Maintenance

    The following table lists the maintenance cycles for the retrofit kit for pressure regulator. By conducting regular maintenance, Schaller Automation guarantees that the product will have a long service life. If the maintenance intervals are not observed, the oil mist detector may fail prematurely. It is essential that you follow the given sequence for the work.
  • Page 3 VN115 - 151489 VN116 - 151487 VN215 - 151488 SCHALLER AUTOMATION D-66440 Blieskastel / Saarland / Germany / Industriering 14 / P.O Box 1280 Tel. +49(0)6842-508-0 Fax -260 / eMail: info@schaller.de / www.schaller-automation.com Industrielle Automationstechnik GmbH & Co. KG...
  • Page 4 366717 365197 Figure 1 : Maintenance kit – Part No. 151490 SCHALLER AUTOMATION D-66440 Blieskastel / Saarland / Germany / Industriering 14 / P.O Box 1280 Tel. +49(0)6842-508-0 Fax -260 / eMail: info@schaller.de / www.schaller-automation.com Industrielle Automationstechnik GmbH & Co. KG...
  • Page 5 Scavenging air insert (2 pcs per bag.) 4 x 360251 Table 1: content of maintenance kit 151490 SCHALLER AUTOMATION D-66440 Blieskastel / Saarland / Germany / Industriering 14 / P.O Box 1280 Tel. +49(0)6842-508-0 Fax -260 / eMail: info@schaller.de / www.schaller-automation.com...
  • Page 6 Cotton sticks to clean IR-filters Bottle with cleaning fluid Table 2: content of maintenance kit 151482 SCHALLER AUTOMATION D-66440 Blieskastel / Saarland / Germany / Industriering 14 / P.O Box 1280 Tel. +49(0)6842-508-0 Fax -260 / eMail: info@schaller.de / www.schaller-automation.com...
  • Page 7 1.2.3 Service kit 151489 VN115/93 Figure 3 : Service kit VN115/93 – Part No. 151489 SCHALLER AUTOMATION D-66440 Blieskastel / Saarland / Germany / Industriering 14 / P.O Box 1280 Tel. +49(0)6842-508-0 Fax -260 / eMail: info@schaller.de / www.schaller-automation.com Industrielle Automationstechnik GmbH & Co. KG...
  • Page 8 360136 Oil return gasket Table 3: content of maintenance kit 151489 SCHALLER AUTOMATION D-66440 Blieskastel / Saarland / Germany / Industriering 14 / P.O Box 1280 Tel. +49(0)6842-508-0 Fax -260 / eMail: info@schaller.de / www.schaller-automation.com Industrielle Automationstechnik GmbH & Co. KG...
  • Page 9 1.2.4 Service kit 151487 VN116/93 Figure 4 : Service kit VN116/93 – Part No. 151487 SCHALLER AUTOMATION D-66440 Blieskastel / Saarland / Germany / Industriering 14 / P.O Box 1280 Tel. +49(0)6842-508-0 Fax -260 / eMail: info@schaller.de / www.schaller-automation.com Industrielle Automationstechnik GmbH & Co. KG...
  • Page 10 360133 Sealing for suction channel in valve box Table 4: content of maintenance kit 151487 SCHALLER AUTOMATION D-66440 Blieskastel / Saarland / Germany / Industriering 14 / P.O Box 1280 Tel. +49(0)6842-508-0 Fax -260 / eMail: info@schaller.de / www.schaller-automation.com Industrielle Automationstechnik GmbH & Co. KG...
  • Page 11 1.2.5 Service kit 151488 VN215/93 Figure 5 : Service kit VN215/93 – Part No. 151488 SCHALLER AUTOMATION D-66440 Blieskastel / Saarland / Germany / Industriering 14 / P.O Box 1280 Tel. +49(0)6842-508-0 Fax -260 / eMail: info@schaller.de / www.schaller-automation.com Industrielle Automationstechnik GmbH & Co. KG...
  • Page 12 Table 5: content of maintenance kit 151488 Service network Schaller Automation service partner are present in 130 countries. Contact details available on our homepage https://schaller-automation.com/en/partners/ You can also contact our technical support at our HQ in Germany : Tel. +49 6842 508 0 SCHALLER AUTOMATION D-66440 Blieskastel / Saarland / Germany / Industriering 14 / P.O Box 1280...