schmersal SRB211AN V.2 Operating Instructions Manual
schmersal SRB211AN V.2 Operating Instructions Manual

schmersal SRB211AN V.2 Operating Instructions Manual

Safety relay module

Advertisement

Quick Links

Operating instructions
Safety relay module
Operating instructions. . . . . . . . . . . . .pages 1 to 8
EN
Original
Content
1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
2.6 Derating curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
5.1 LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.2 Description of the terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
5.3 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
5.4 Setting report SRB 211 AN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
SRB211AN V.2 / CC V.2 / PC V.2
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8
8.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
8.2 Start configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
8.3 Sensor configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
8.4 Actuator configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
9
EU Declaration of conformity
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety-monitoring module. The
operating instructions must be available in a legible condition and a
complete version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional
information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed
to execute safety-related functions as part of an entire plant or machine.
It is the responsibility of the manufacturer of a machine or plant to
ensure the correct functionality of the entire machine or plant.
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
EN
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRB211AN V.2 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal SRB211AN V.2

  • Page 1 Operating instructions Safety relay module SRB211AN V.2 / CC V.2 / PC V.2 Disassembly and disposal 7.1 Disassembly......... . .5 7.2 Disposal .
  • Page 2 Operating instructions Safety relay module SRB211AN V.2 / CC V.2 / PC V.2 There are no residual risks, provided that the safety instructions as well The safety function is defined as the opening of the enabling circuits as the instructions regarding mounting, commissioning, operation and 13-14 and 23-24 and the delayed opening of the enabling circuits 37-38 maintenance are observed.
  • Page 3 Operating instructions Safety relay module SRB211AN V.2 / CC V.2 / PC V.2 Electrical data: Contact load op/y cycle Contact resistance in new state: max. 100 mΩ Power consumption: 2.4 W / 5.9 VA, plus signalling output 20 % 525,600 1.0 min...
  • Page 4 Operating instructions Safety relay module SRB211AN V.2 / CC V.2 / PC V.2 5. Operating principle and settings Time setting (see Fig. 4 and 5) 5.1 LED functions DIP switch settings: • K1: Status channel 1 • The DIP switches are located underneath the front cover of •...
  • Page 5 Operating instructions Safety relay module SRB211AN V.2 / CC V.2 / PC V.2 6. Set-up and maintenance 5.3 Notes Delayed enabling circuits (see Fig. 6) 6.1 Functional testing • The drop-out delay of the safety enabling circuits 37-38 can be The safety function of the safety-monitoring module must be tested.
  • Page 6 Operating instructions Safety relay module SRB211AN V.2 / CC V.2 / PC V.2 8. Appendix 8.3 Sensor configuration 8.1 Wiring examples Dual-channel emergency stop circuit with command devices to ISO 13850 and IEC 60947-5-5 (Fig. 11) Dual-channel control, shown for a guard door monitor; with two •...
  • Page 7 Operating instructions Safety relay module SRB211AN V.2 / CC V.2 / PC V.2 8.4 Actuator configuration Single-channel control with feedback circuit (Fig. 14) • Suitable for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts.
  • Page 8 Operating instructions Safety relay module SRB211AN V.2 / CC V.2 / PC V.2 9. EU Declaration of conformity EU Declaration of conformity Original K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.

This manual is also suitable for:

Srb211an/pc v.2Srb211an/cc v.2

Table of Contents