1

About this document

1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
5.1 LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.2 Description of the terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.3 Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8
8.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.2 Start configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.3 Sensor configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.4 Actuator configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
9
EU Declaration of conformity
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety-monitoring module. The
operating instructions must be available in a legible condition and a
complete version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional
information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications. There
are no residual risks, provided that the safety instructions as well as
the instructions regarding mounting, commissioning, operation and
maintenance are observed.
EN
SRB 301MC
SRB 301MC-ST
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRB 301MC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for schmersal SRB 301MC

  • Page 1 5.3 Notes ..........4 Further technical information can be found in the Schmersal...
  • Page 2 Operating instructions SRB 301MC Safety relay module SRB 301MC-ST 1.6 Warning about misuse 2.4 Technical data General data: In case of inadequate or improper use or manipulations of Standards: IEC 60204-1, IEC 60947-5-1,ISO 13849-1, IEC 61508 the safety-monitoring module, personal hazards or damage...
  • Page 3 IEC 60947-5-1 feed cables must be designed for the highest voltage, which Dimensions H x W x D: SRB 301MC: 100 x 22.5 x 121 mm can occur in the device. SRB 301MC-ST: 120 x 22.5 x 121 mm The electrical connection may only be carried out by The data specified in this manual are applicable when the component is authorised personnel in a de-energised condition.
  • Page 4 Operating instructions SRB 301MC Safety relay module SRB 301MC-ST 6. Set-up and maintenance 5.3 Notes Signalling outputs must not be used in safety circuits. 6.1 Functional testing The safety function of the safety-monitoring module must be tested. The following conditions must be previously checked and met: Due to the operating principle of the electronic fuse, the cus- 1.
  • Page 5 ISO 14119 (see Fig. 12) • When the SRB 301MC safety-monitoring module is used with • At least one contact with positive break required. the operating mode "Automatic start", an automatic restart after a •...
  • Page 6 • Category 4 – PL e to ISO 13849-1 possible. The connection of magnetic safety switches to the Fig. 16 Fig. 17 SRB 301MC safety-monitoring module is only admitted when the requirements of the standard IEC 60947-5-3 are observed. As the technical data are regarded, the following minimum requirements must be met: –...
  • Page 7 SRB 301MC Safety relay module SRB 301MC-ST 9. EU Declaration of conformity EU Declaration of conformity Original K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.
  • Page 8 K.A. Schmersal GmbH & Co. KG Möddinghofe 30, 42279 Wuppertal Germany Phone: +49 202 6474-0 Telefax: +49 202 6474-100 E-Mail: info@schmersal.com Internet: www.schmersal.com...