schmersal FWS 2105 Operating Instructions Manual
schmersal FWS 2105 Operating Instructions Manual

schmersal FWS 2105 Operating Instructions Manual

Fail-safe standstill monitor

Advertisement

Quick Links

Operating instructions
Fail-safe standstill monitor
EN
Operating instructions...................... pages 1 to 6
Translation of the original operating instructions
Vous trouverez la version
FR
actuelle du mode d'emploi
dans votre langue nationale
oficielle sur l'Internet,
www.schmersal.net.
U vindt de huidige versie van
NL
de gebruikshandleiding in uw
oficiële landstaal op het Inter-
net, www.schmersal.net.
EU公用語で書かれた最新の
JP
取扱説明書は、インターネッ
(www.schmersal.net)からダウ
ンロードできます。
Content
1
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualiied personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Destination and use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classiication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
8
8.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8.2 Integral System Diagnostics (ISD) . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.3 Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Encontrará el manual de
ES
instrucciones actual en su
idioma oicial de la UE en
nuestra página de Internet
www.schmersal.net.
Il manuale d'istruzioni aggior-
IT
nato nella vostra lingua (lin-
gua uficiale UE) è scaricabile
in Internet all'indirizzo
www.schmersal.net.
1 About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning for the safe operation
and disassembly of the safety-monitoring module. The operating
instructions must be available in a legible condition and a complete
version in the vicinity of the device.

1.2 Target group: authorised qualiied personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical speciications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the proper functionality of the entire machinery or plant.
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country-speciic installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the
Schmersal catalogues or in the online catalogue
on the Internet: www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modiications.
The entire concept of the control system, in which the
safety component is integrated, must be validated to
EN ISO 13849-2.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.

1.6 Warning about misuse

In case of inadequate or improper use or manipulations of
the safety-monitoring module, personal hazards or damages
to machinery or plant components cannot be excluded. The
relevant requirements of the standard EN 1088 must be
observed.
EN
FWS 2105
FWS 2505
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FWS 2105 and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal FWS 2105

  • Page 1: Table Of Contents

    Further technical information can be found in the Electrical connection Schmersal catalogues or in the online catalogue 4.1 General information for electrical connection....3 on the Internet: www.schmersal.net.
  • Page 2: Exclusion Of Liability

    Standstill frequencies of the inputs X2/X4: Hysteresis: 10% of the standstill frequency ➀ 1 Hz/2 Hz Max. input frequency: FWS 2105: 4000 Hz Min. impulse duration: FWS 2105: 125 μs 1 Hz/1 Hz Outputs: Stop category 0: FWS 2105: 1...
  • Page 3: Safety Classiication

    FWS 2105 Fail-safe standstill monitor FWS 2505 2.5 Safety classiication Outputs FWS 2105: (13/14) NO contact for safety functions (enabling path) Standards: EN ISO 13849-1; IEC 61508 FWS 2505: (13/14)-(23/24)-(33/34)-(43/44) NO contacts for safety up to d functions (enabling paths)
  • Page 4: Appendix

    ≥ 50 mA on the safety guard as a replacement for the NO contact of the AZM 161 in order to achieve PL d or control category 3. e.g. Schmersal IFL ..-..-10 P FWS 2105 AZM 161-12/12 22 41...
  • Page 5: Integral System Diagnostics (Isd)

    Operating instructions FWS 2105 Fail-safe standstill monitor FWS 2505 Legend Table error indications Indication (orange) Error Cause Positive break Frequency sensor 1 1 impulse Defective lead Proximity switches too low, Defective proximity Error input X2 switch Reset button 2 impulses...
  • Page 6: Declaration Of Conformity

    Authorised signature Heinz Schmersal Managing Director Note The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. K. A. Schmersal GmbH Industrielle Sicherheitsschaltsysteme Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal...

This manual is also suitable for:

Fws 2505

Table of Contents