schmersal SRB 400C Operating Instructions Manual
schmersal SRB 400C Operating Instructions Manual

schmersal SRB 400C Operating Instructions Manual

Safety relay module

Advertisement

Quick Links

Operating instructions
Safety relay module
Operating instructions. . . . . . . . . . . . .pages 1 to 8
EN
Original
Content
1
About this document
1.1 Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.2 Target group: authorised qualified personnel. . . . . . . . . . . . . . . . . .1
1.3 Explanation of the symbols used . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.4 Appropriate use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.5 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1
1.6 Warning about misuse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
1.7 Exclusion of liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2
2.1 Ordering code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.2 Special versions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.3 Purpose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.4 Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
2.5 Safety classification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3
3.1 General mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
3.2 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
4
4.1 General information for electrical connection. . . . . . . . . . . . . . . . . .3
5
5.1 LED functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
5.2 Description of the terminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
6
6.1 Functional testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
6.2 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7
7.1 Disassembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
7.2 Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8
8.1 Wiring examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
8.2 Start configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.3 Sensor configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
8.4 Actuator configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
8.5 Flowcharts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7
9
EU Declaration of conformity
1. About this document

1.1 Function

This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety-monitoring module. The
operating instructions must be available in a legible condition and a
complete version in the vicinity of the device.

1.2 Target group: authorised qualified personnel

All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.

1.3 Explanation of the symbols used

Information, hint, note:
This symbol is used for identifying useful additional
information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.

1.4 Appropriate use

The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety-monitoring module must be exclusively used in accordance
with the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".

1.5 General safety instructions

The user must observe the safety instructions in this operating
instructions manual, the country specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the online
catalogue on the Internet: products.schmersal.com.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
EN
SRB 400C...
SRB 400SNA
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SRB 400C and is the answer not in the manual?

Questions and answers

Summary of Contents for schmersal SRB 400C

  • Page 1: Table Of Contents

    5.2 Description of the terminals .......3 catalogue on the Internet: products.schmersal.com.
  • Page 2: Warning About Misuse

    Operating instructions SRB 400C… Safety relay module SRB 400SNA 1.6 Warning about misuse The safety function is defined as the opening of the enabling circuits 13-24 and 33-44 when the inputs S31-S32 and/or S41-S42 (S43-S44) In case of inadequate or improper use or manipulations of...
  • Page 3: Safety Classification

    Operating instructions SRB 400C… Safety relay module SRB 400SNA 4. Electrical connection Number of NO contacts: SNA, CS, CS/T: 0x CA, CA/T, CA/Q, CA/QT: 1x Number of NC contacts: SNA, CS, CS/T: 4x 4.1 General information for electrical connection CA, CA/T, CA/Q, CA/QT: 3x...
  • Page 4: Set-Up And Maintenance

    Operating instructions SRB 400C… Safety relay module SRB 400SNA 8. Appendix 8.1 Wiring examples 24 14 13 33 Dual-channel control, shown for an emergency stop circuit; S22 S12 A1 with two contacts A and B and a guard door monitor with two contacts C and D, where at least one is a positive break contact;...
  • Page 5: Start Configuration

    Operating instructions SRB 400C… Safety relay module SRB 400SNA 24 VDC 0 V Automatic start (see Fig. 7) • The automatic start is programmed by connecting the feedback circuit to the terminals X1 (referring to the switch-off level 1) and X2 (referring to the switch-off level 2).
  • Page 6: Actuator Configuration

    Operating instructions SRB 400C… Safety relay module SRB 400SNA 8.3.2 Sensor configuration - partially functioning switch-off level 2 For example, the following safety sensors meet the requirements: Single-channel guard door monitoring circuit with interlocking BNS 33-11z, BNS 33-12z-2063, BNS 33-11z-2063 devices to ISO 14119 (Fig.
  • Page 7: Flowcharts

    Operating instructions SRB 400C… Safety relay module SRB 400SNA 8.5 Flowcharts SRB 400CA/T, SRB 400CS/T, SRB 400CA/QT see Fig. 18 SRB 400CA, SRB 400CS, SRB 400CA/Q, SRB 400SNA see Fig. 17 Fig. 18 Fig. 17 a) U a) U b) Sensor level 1...
  • Page 8 Safety relay module SRB 400SNA 9. EU Declaration of conformity EU Declaration of conformity Original K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives.

This manual is also suitable for:

Srb 400snaSrb 400ca: srb 400csSrb 400ca/tSrb 400cs/tSrb 400ca/qSrb 400ca/qt

Table of Contents