2. Fill water to the lower surface of the discharge
outlet (B).
B
3. Install and tighten the pump chamber cap.
Installation
To install the product
1. Put the product on stable and level ground near
the water surface.
2. Make sure that the product has a free space of a
minimum of 1 m.
3. Make sure that there are no flammable objects
near the engine.
4. Make sure that the level difference for the
suction hose (A) is as low as possible for the
operation. The level difference for the suction hose
must not be more than 7.5 m/25 ft.
C
Note: The level difference for the discharge hose
(B) can be more if it is necessary. But, a lower total
level difference (C) gives the best result.
To install suction hose
1. Attach the hose connector (D) to the suction
hose (F) with a hose clamp (E). Make sure that the
sealing washer for the hose connector is in good
condition.
2. Install the strainer (H) at the end of the suction
hose with the hose clamp (G).
3. Tighten the hose connector on the pump suction
inlet (C).
G
H
E
F
To install discharge hose
1. Attach the hose connector (I) to the pump outlet.
B
2. Install the discharge hose (K) to the hose
connector and tighten the hose clamp (J).
A
C
D
E
F
D
I
J
K