Operation At High Altitude; Maintenance; Cleaning The Generator - Champion 201242 Operator's Manual

5500w portable inverter generator
Table of Contents

Advertisement

201242 - 5500W PORTAbLE INvERTER GENERATOR
1. Begin by raising the folding handle, found on opposite side of
wheels.
2. Press the button inside the handle as shown below and
extend the telescoping handle until a click is heard and the
handle is locked in its fully extended position.
3. Using the handle, tilt the end of the generator slightly off the
ground until balanced on the wheels.
4. While maintaining balance, roll the generator to the desired
location.

Operation at High Altitude

The density of air at high altitudes is lower than at sea level.
Engine power is reduced as the air mass and air-fuel ratio
decrease. Engine power and generator output will be reduced
approximately 3½% for every 1000 ft. of elevation above sea level.
At high altitudes increased exhaust emissions can also result due
to the increased enrichment of the air fuel ratio. Other high altitude
issues can include hard starting, increased fuel consumption and
spark plug fouling.
To alleviate high altitude issues other than the natural power
loss, CPE can provide a high altitude carburetor main jet. The
alternative main jet and installation instructions can be obtained
by contacting our Technical Support Team. Installation instructions
are also available in the Technical Bulletin area of the CPE website.
Operation using the alternative main jet at elevations lower
than the recommended minimum altitude can damage the
engine. For operation at lower elevations, the originally
supplied standard main jet must be used. Operating the
engine with the wrong engine configuration at a given altitude
may increase its emissions and decrease fuel efficiency and
performance.
WARNING

MAINTENANCE

Make certain that the generator is kept clean and stored properly.
Only operate the unit on a flat, level surface in a clean, dry
operating environment. DO NOT expose the unit to extreme
conditions, excessive dust, dirt, moisture or corrosive vapors.
Never operate a damaged or defective generator.
Improper maintenance will void your warranty.
For Emission control devices and systems, read and
understand your responsibilities for service as stated in the
Emission Control Warranty Statement of this manual.
The owner/operator is responsible for all periodic maintenance.
Complete all scheduled maintenance in a timely manner.
Correct any issue before operating the generator.
For service or parts assistance, contact our
Technical Support Team at 1-877-338-0999.

Cleaning the Generator

DO NOT spray generator directly with water.
Water can enter the generator through the cooling slots and
damage the generator windings. It can also contaminate the
fuel system.
1. Use a damp cloth to clean exterior surfaces of the generator.
2. Use a soft bristle brush to remove dirt and oil.
3. Use an air compressor (25 PSI) to clear dirt and debris from
the generator.
4. Inspect all air vents and cooling slots to ensure that they are
clean and unobstructed.
To prevent accidental starting, remove and ground the spark plug
wire before performing any service.
25
MAINTENANCE
WARNING
WARNING
NOTICE
CAUTION

Advertisement

Table of Contents
loading

Table of Contents