Removing And Reinstalling The Main Parts; Test Mode - Sharp XL-70V Service Manual

Video cd micro system
Table of Contents

Advertisement

XL-70V
The test mode applied to this microcomputer has three modes, namely ordinary test mode to be used for adjustment or
measurement, aging test mode to be used for aging test, and self-diagnosis test mode for self-inspection in case of final product
inspection.
1. Turning on the test mode
To turn on the specific test mode, press the POWER button, holding down the following two buttons in the ordinary stand-by
mode (power off state). In this case only the main unit button is valid. Even when the POWER of remote control button is set
to on, the test mode is not turned on.
[Ordinary test mode]
1. Tuner Test Mode (TEST 2) ............................... Volume/JOG Dial Selector + Volume Select
2. Electronic volume Test Mode (TEST 3) ........... REW/REV + FF/FWD
3. Timer Test Mode (TEST 4) ............................... FUNCTION + Volume Select
4. LCD Test Mode (TEST 5) ................................. FUNCTION + FF/FWD
[Self-diagnosis test mode]
1. Button input diagnosis test mode (TEST 6)...... REW/REV + Volume Select
2. Tuner Test Mode (TEST 2)
1. Outline of tuner (radio) test mode
The tuner test mode is intended to store the adjustment and measurement frequencies in the preset memory CH without
frequency setting by adjusting personnel when the tuner section is adjusted in the production line.
2. Details of tuner test mode
When the power is turned on by using the "POWER" button while the "Volume/JOG Dial Selector" and "Volume Select"
buttons are held down in POWER OFF state, the frequency for adjustment and measurement of destination specified by the
AREA terminal is preset and stored in the preset memory CH. However, Ordinary 1 and Ordinary 2 are set to the designation
(destination selected by SPAN switching operation) set when the test mode is set. (As for frequencies to be preset and stored
for each destination, refer to item 3.)
The tuner test mode is started from preset No.1.
The operations of test mode are identical with the ordinary operations of TUNER function. However, FUNCTION switching
is invalid.
Since it is necessary to discard the content of preset memory when the tuner test mode is ended, "0000" or "1111" bits are
written in the memory to be checked in case of memory check (in case of initial setting) so that memory abnormality is detected
in case of initial setting so as to ensure memory initialization.
When the tuner test mode is turned on, the following indication lights for one second.
• The TUNER TEST 2 mode is set as a result of Volume Select + POWER. -> IF AC is set to OFF in the TEST 2 mode, the initial
• To clear the whole memory, insert the AC cord, holding down MEMORY + PLAY.

TEST MODE

When POWER is set to OFF, the memory of TEST 2 mode is protected.
When the power is turned on again, the ordinary operation is enabled while the data is stored in the
memory (besides TUNER).
If AC OFF state is maintained in this state for about 1/2 day, start is executed in the initial state.
state is restored.