Carrier TOSHIBA MMK-UP0151HP-UL Service Manual page 117

Mult type
Table of Contents

Advertisement

How to remove the drains cap
Clip the drain cap by needle-nose pliers and pull out.
How to fix the drains cap
1) ) Insert hexagonal wrench (dia. 0.2" (4 mm)) in a centre hea
2) ) Firmly insert drains cap.
Do not apply lubricating oil
(refrigerant machine oil) when
inserting the drain cap. Application
causes deterioration and drain
leakage from the plug.
Firmly insert the drain hose and drain cap; otherwise, water may leak.
In case of right or left piping
• After scribing slits of the front panel with a knife or a marking-off pin, cut them with a pair of nippers or
an equivalent tool.
No gap
CAUTION
Slit
- 117 -
Insert a hexagon
wrench 0.2" (4 mm)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Toshiba mmk-up0181hp-ulToshiba mmk-up0241hp-ul

Table of Contents