5
After finishing setting the data of the item
code (DN), press [
"Continue?" is displayed.
6
To set the data of other item codes (DN),
press [
Set/Fix]
To not do other settings, press [
The changes are fixed, and the "Field setting
menu" screen returns.
" " appears while data is changing.
When doing group connections:
Press [
Return] to open the unit selection
screen. In the unit selection screen, press
[
Return] to briefly display " ", and then
return to the "Field setting menu" screen.
Change of lighting time of filter
sign
According to the installation condition, the lighting
time of the filter sign (Notification of filter cleaning)
can be changed.
Follow to the basic operation procedure
1
2
3
4
5
(
• For the CODE No. in Procedure
• For the [SET DATA] in Procedure
SET DATA of filter sign lighting time from the
following table.
SET DATA
Filter sign lighting time
0000
0001
150H (Factory setting)
0002
0003
0004
To secure better effect of heating
When it is difficult to obtain satisfactory heating
due to installation place of the indoor unit or
structure of the room, the detection temperature of
heating can be raised. Also use a circulator, etc.
to circulate heat air near the ceiling.
Follow to the basic operation procedure
1
2
3
4
5
(
• For the CODE No. in Procedure
• For the SET DATA in Procedure
SET DATA of shift value of detection
temperature to be set up from the table below.
Set/Fix]
Return]
6
).
3
, specify [01].
4
, select the
None
2500H
5000H
10000H
6
).
3
, specify [06].
4
, select the
SET DATA
0000
0001
0002
0003
0004
0005
0006
Changing the wind direction
Up / down direction: Horizontal louvres
* Display while swingin
1
Press [
] and [
"Wind direction" screen (horizontal louvres)
2
Press [
] and [
direction
Operation mode
Heat, Fan, Auto (Heat)
Cool, Dry, Auto (Cool)
- 131 -
Detection temp shift value
No shift
+1.8°F (+1°C)
+3.6°F (+2°C) (Factory setting)
+5.4°F (+3°C)
+7.2°F (+4°C)
+9°F (+5°C)
+10.8°F(+6°C)
] to switch to the
] to select wind
Settable angles
(1), (2), (3), (4), (5),
Swing
(1), (2), (3), Swing