2-8.5 Jp1&Jp7: PS/2 KB/Mouse Power On
Jp1 and Jp7 is designed to enable / disable PS/2 Keyboard/Mouse Power
on function. Setting Jp1 and Jp7 to 1-2 closed will disable this function.
Setting Jp1 and Jp7 to 2-3 closed will enable this function. Yet user still
has to enter BIOS Setup for choosing the KB/ Mouse Power-on mode.
(See Integrated Peripherals" in BIOS Setup.)
1
1

2-8.6 Jp4: SATA RAID Controller Select(75MRN2-R/RL Only)

Jp4 is a 3-pin jumper for enabling or disabling the on-board Serial ATA
RAID Controller PDC20376. Setting Jp4 1-2 CLOSED will allow user to
enable on-board RAID Controller so as to allow user to set up the Disk
Array.
Jp1&Jp7:
PS/2 Keyboard/Mouse Power On
1-2 closed (default)
PS/2 KB/Mouse Power
1
On Disabled
2-3 closed
1
PS/2 KB/Mouse
Power On Enabled
Jp4: (75FRN2-R/RL Only)
Serial ATA RAID Select
1
1-2 closed (default)
SATA RAID Controller enabled
1
2-3 closed
SATA RAID Controller disabled
30