Capturing Debug Logs On The Wlc Reference Board - Infineon WLC1150 User Manual

Mp-a2 50-w wireless power transmitter
Table of Contents

Advertisement

WLC1150 MP-A2 50-W wireless power transmitter
(REF_WLC_TX50W_N1) user guide
Reference board operation
4.3

Capturing debug logs on the WLC reference board

This section explains the procedure to capture the debug logs sent on the serial port of the
reference board at various stages of the operation. This feature helps to understand the
REF_WLC_TX50W_N1
internal operation of the firmware in addition to the status LED indication available on the board.
To capture the debug log, follow these steps:
1. Install data logging software on the PC.
Download a data logging tool, such as Tera Term, and install it on the PC.
a)
2. Enable the debug log in the firmware.
Download the Wireless Charging Utility package from the
a)
install it on the PC.
Create the USB CC communication-based
b)
set-up to configure the firmware using Wireless Charging Configuration Utility.
Open the Wireless Charging Configuration Utility from the Start menu in Windows.
c)
Confirm that the reference board is selected under the Device Selection tab, as shown in
d)
Figure 15
Selective device in Wireless Charging Configuration Utility
Click Tools > Read from Device or select the Read from Device option from the Home panel. This
e)
enables the user to read the configuration from the device.
The debug log can be enabled by configuring the following parameters in the transmitter Profile page in
f)
the Wireless Charging Configuration Utility, see
o Enable Critical log enable
o Enable Message log enable
o Set Debug log to Level 1
User guide
REF_WLC_TX50W_N1
(Figure
10) or I2C communication-based
Figure
16.
23
release package and
(Figure
14) hardware
Figure
15.
002-36393 Rev. *B
2023-02-06

Advertisement

Table of Contents
loading

Table of Contents