Battery; Fuse; Connector - wsm Kubota M128X Workshop Manual

Table of Contents

Advertisement

M128X, WSM

[2] BATTERY

[3] FUSE

[4] CONNECTOR

• Take care not to confuse positive and negative terminals.
• When removing battery cable, disconnect negative wire first.
When installing battery cable, check for polarity and connect
positive wire first.
• Do not install any battery with capacity other than is specified
(Ah).
• After connecting cable to battery terminals, apply grease to them
and securely install terminal covers on them.
• Do not allow dirt and dust to collect on battery.
CAUTION
• Take care not to let battery liquid spill on your skin and
clothes. If contaminated, wash it off with water immediately.
• Before recharging the battery, remove it from the machine.
• Before recharging, remove cell caps.
• Do recharging in a well-ventilated place where there is no
open flame nearby, as hydrogen gas and oxygen are formed.
• Use fuses with specified capacity.
Neither too large or small capacity fuse is acceptable.
• Never use steel or copper wire in place of fuse.
• Do not install working light, radio set, etc. on machine which is not
provided with reserve power supply.
• Do not install accessories if fuse capacity of reserve power
supply is exceeded.
(1) Fuse
• For connector with lock, push lock to separate.
(A) Push
• In separating connectors, do not pull wire harnesses.
• Hold connector bodies to separate.
(A) Correct
G-5
G GENERAL
W1011816
(2) Slow Blow Fuse
W1012092
W1012211
(B) Incorrect
W1012272
KiSC issued 07, 2008 A