PDH / DSn Testing With The HP 37717C
Monitoring DS3 with ATM Payloads
Monitoring DS3 with ATM Payloads
Option Required DS1, DS3, E1 and E3 Transmit and Receive Interfaces for ATM
Payloads. Option UKZ
Connect the HP 37717C RECEIVE DS3
IN to the network monitor point, select
the
display and DS3 rate.
RECEIVE
Select the convergence layer, Direct or
PLCP.
Select
RESULTS
for the physical
PDH
and convergence layer results.
67