Installation Guide
Installation Guide, Part Number 151657 A1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the INFINIX SPLICE and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Amphenol INFINIX SPLICE

  • Page 1 Installation Guide Installation Guide, Part Number 151657 A1...
  • Page 2 Liberty Lake, WA 99019 Amphenol Network Solutions assumes no liability from the application or use of these products. Neither does Amphenol Network Solutions convey any license under its patent rights nor the patent rights of others. This document and the products described herein are subject to change without notice.
  • Page 3: Table Of Contents

    5.1 Determining Correct Split Sleeve Breakouts .................. 25 5.1.1 Split Sleeve Breakouts ......................25 5.2 Cable Preparation .......................... 26 5.2.1 Fiber and Sleeve Lengths ....................26 Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3 509.926.6000 — amphenol-ns.com...
  • Page 4 Figure 4-7 Secure Splice Rack to Wall ....................21 Figure 4-8 IFC Entry Bracket and Tie Off Brackets ................21 Figure 4-9 Mounting Cable Manager ....................22 Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 5 Figure 9-9-10 Completed Fiber Slack Storage ..................47 Figure 10-1 Side Panel Tabs ....................... 48 Figure 10-2 Installing Frame Covers ....................48 Figure 10-3 Door Hinges on Cable Manager ..................49 Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3 509.926.6000 — amphenol-ns.com...
  • Page 6: Section One: Introduction

    Installation Guide Section One: Introduction Amphenol Network Solutions InfinX Splice™ is a high-density fiber splice platform providing optimal fiber protection and access in a single design and is engineered for high-capacity data center applications. Unique slide-out trays provide easy access to optical splices.
  • Page 7: About This Guide

    This manual provides a comprehensive overview of and installation guidelines for the INFINX SPLICE Platform. While care has been taken to define all necessary information, complete details may not be covered. If you have any questions, contact Amphenol Network Solutions Technical Support at support@Amphenol-NS.com or call 1-509-926-6000.
  • Page 8: Terminology

    WARNING! Indicates a potentially hazardous situation which could result in death or serious injury. Amphenol Network Solutions assumes no liability from the application or use of these products. Amphenol Network Solutions does not convey any license under its patent rights nor the patent rights of others. This document and the products described herein are subject to change without notice.
  • Page 9: Section Two: Infinx Splice Overview

    The INFINX SPLICE Tray slides in and out by depressing the black locking tabs on the side of Splice Drawer and pulling down. This allows for easy access to the fiber and Splice Cradles. Figure 2-2 Release Tabs Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 10: Splice Cradle

    The INFINX SPLICE Cradle allows 12 x 12 fiber mass fusion splices = 144 fibers per cradle. With 6 cradles per stack and 2 stacks, each drawer allows 1728 splices. Figure 2-4 Splice Cradles Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 11: Sleeve Entry Bracket

    OSP/IFC cable can enter the frame from the bottom, top, or sides based on individual needs. The Wall Mount Frame includes all necessary brackets for routing fiber within. Sleeve Entry Brackets Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 12: Wall Mount Splice Rack Components

    IFC entry on each side as well as Cable Termination Brackets for securing OSP below the frame. Components of the Wall Mount Bracket include: Horizontal Hanger • • Vertical Lacing Bar Cable Termination Bracket • Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3 509.926.6000 — amphenol-ns.com...
  • Page 13 Installation Guide Horizontal Hanger Vertical Lacing Bar Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3 509.926.6000 — amphenol-ns.com...
  • Page 14: Splice Rack

    Splice Rack on 5/8" centers, H/W not included) Spacer Bracket Cable Manager Sleeve Entry Bracket Door Latch Tie Off Bracket Figure 2-8 Splice Rack Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3 509.926.6000 — amphenol-ns.com...
  • Page 15: Frame Covers

    Tie off Brackets • Sleeve Entry Brackets Hose Clamps and Hook and Loop Kits • • Split Sleeve Breakout Kit re 2-10 Fiber Manager Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3 509.926.6000 — amphenol-ns.com...
  • Page 16: Section Three: Installation Considerations

    OSP Strength Member Bracket Kit – optional • 3.2 Inspection Please report any defective or missing parts to Amphenol-Network Solutions Quality at quality@amphenol- ns.com or call 1-509-926-6000. Keep all documentation that comes with your shipment. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved.
  • Page 17: Installation Guidelines

    Amphenol Network Solutions Technical Support at support@Amphenol-ns.com or call 1-509-926-6000. Exercise care when unpacking and setting the equipment in place. Amphenol Network Solutions is not liable for transit damage. If the product is damaged, please report it to the carrier and contact Amphenol Network Solutions Quality at quality@amphenol-ns.com 3.3 Installation Guidelines...
  • Page 18: Figure 4-1Installing Top Horizontal Hanger

    5. Secure the bottom Horizontal Hanger to the wall using 3/8”-1/2” lag bolts for wood or 3/8”-1/2” concrete anchors for cinder block or concrete. Mounting hardware is NOT included. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 19: Figure 4-3 Installing Cable Termination Bracket

    Figure 4-4 Tie down brackets (optional) ALERT! Weight of the Splice Rack requires two-person lift. The frame is bolted to the pallet upside down and must be flipped before installation. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 20: Figure 4-5 Splice Frame Stops

    9. Verify the Splice Rack is level and square by measuring from the edge of frame to outer edge of Vertical Lacing Bar. Figure 4-6 Installing Splice Rack Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 21: Figure 4-7 Secure Splice Rack To Wall

    12. There is a left and right Vertical Cable manager. Hang the Vertical Cable Manager to the outside of the frame by inserting the tab from the Vertical Cable Manager into the slot on top of the frame. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved.
  • Page 22: Figure 4-9 Mounting Cable Manager

    Cover Outboard Figure 4-11 Hang Right Vertical Cable Manager 15. Repeat steps 9-14 to hang the second Splice Rack and Vertical Cable Manager onto Wall Mount Bracket. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 23: Figure 4-12 Hang Second Splice Rack

    Routing Bracket is secured to the frame with the included 12-24 screws. Mounting positions Routing Bracket Figure 4-13 Installing Routing Bracket (S) 17. Install Door Latches on Splice Racks using included 1/4-20 bolts and nuts Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3 509.926.6000 — amphenol-ns.com...
  • Page 24: Figure 4-14 Install Door Latches And Middle Spacer Bracket

    NOTE: The Top and Bottom Spacer Brackets have tapped holes on the front. Top and Bottom Spacer Brackets Figure 4-15 Install Top and Bottom Spacer Brackets Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3 509.926.6000 — amphenol-ns.com...
  • Page 25: Section Five: Prepping Osp And Ifc Fiber Cables

    Prysmian 3456f Loose Buffer Tube 1/2" 864f Sumitomo 6912f Slotted Core 1/2" 864f Sumitomo 1728f Central Core Tube 3/4" 1728f AFL 1728f Wrapping Tube 3/4" 1728f Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3 509.926.6000 — amphenol-ns.com...
  • Page 26: Cable Preparation

    14 ft 5.2.2 Strength Members Cut Lengths 1. For OSP Loose Buffer Tube cables, cut the strength member approximately 4” from the ring cut. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3 509.926.6000 — amphenol-ns.com...
  • Page 27: Installing Sleeve Kits For Osp Cable

    Figure 5-2 Installing Sleeve with Insertion Tool 5. Wrap felt tape on the end of the split sleeve near the ring cut. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 28: Figure 5-3 Taping Sleeve Ends

    Figure 5-5 Taping Back from Ring Cut 9. Cut the included 2” split sleeve to a length of 6”. This sleeve is used to cover the transition from cable jacket to split sleeves. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 29: Installing Sleeve Kits For

    This recouples the strength member to the cable jacket to minimize movement of the strength member relative to the jacket. The Strength Member Bracket Kit contains the Bracket with Strength Member Receptacle, Bushing, and Hose Clamp. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 30: Figure 5-7 Strength Member Bracket

    3. Secure the Strength Member Bracket to the cable using the included hose clamp until hand tight. NOTE: Do not over tighten the Hose Clamp. Tightening the Hose Clamp too much could result in damage to the fiber cable. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 31: Figure 5-9 Securing The Strength Member Bracket

    Installation Guide Figure 5-9 Securing the Strength Member Bracket Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3 509.926.6000 — amphenol-ns.com...
  • Page 32: Section Six: Routing Fiber Into Frame And Splice Drawer

    2. When installing fiber in the right frame, route the first group of 4 x 1728 or 8 x 864 fiber sleeves to the lower Routing Bracket starting at the left most position and secure with supplied 3/4" hook and loop. If installing Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved.
  • Page 33: Figure 6-2 Routing Bracket In Right Frame

    3. Install extra Tie Off Bracket centered between the two racks above the bottom Horizontal Hanger using screws or concrete anchors. Mounting hardware not included. Figure 6-3 Center Tie Off Bracket Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 34: Figure 6-4 Slack Loop

    Tie Off Bracket and prevent the sleeves from crossing. Repeat routing sleeves in descending order to the third, second then first Splice Drawer. Figure 6-5 Tie Off Bracket Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 35: Routing Second Osp (Splice Drawer 5-8 And 9-12)

    9-12. Keep fiber for Splice Drawer 8 in forward most position in Tie Off Bracket. Group 3 Group 2 Group 1 Figure 6-7 Routing Second OSP Group 3. Follow steps 5 and 6 in Section 6.1.1. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3 509.926.6000 — amphenol-ns.com...
  • Page 36: Routing

    4. Secure IFC sleeves to the Tie Off Bracket using supplied 3/4" hook and loop. 5. Repeat steps 1-4 to route IFC cables to Splice Drawer 5-8 and 9-12. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 37: Section Seven: Installing Infinx Splice Drawer

    3. Additional 12-24 screws are zip tied to the mounting bracket. Remove and install additional screws in the top bracket locations and tighten lower screws to secure Splice Drawer in place. Figure 7-2 Splice Drawer Mounting Brackets Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 38: Section Eight: Routing Fiber Into Splice Drawer

    3. Remove the front cover by pulling the black plungers and pulling forward. Black plungers Black plungers Figure 8-1 INFINX SPLICE Drawer Tray Open (2 trays shown) Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3 509.926.6000 — amphenol-ns.com...
  • Page 39: Figure 8-2 Routing To Opposite Side Of Tray

    1” and wrap the end with felt tape to prevent the sleeves from backing out when tray is opened. Tray Tie Down Figure 8-3 Securing Sleeves to Tray Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3 509.926.6000 — amphenol-ns.com...
  • Page 40: Figure 8-4 Tray Fully Closed Position

    Splice Drawer, and a counterclockwise direction for fiber on the left side of the Splice Drawer. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 41: Figure 8-5 Fiber Slack Storage

    14. The next Splice Drawer can now be installed, and fiber can be routed. Repeat steps in section 7 through 8- 13. . Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 42: Section Nine: Splicing

    Removal: Lower ribbon slack loops (orange group) out first, then lower holder stack. Next upper ribbon fiber loops (blue wrap) out first, then upper holder stack. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 43: Figure 9-2 Fiber Routing Instructions

    7. Hold the cradle stack so that the fiber on the left side is going to the left side of the Splice Drawer and fiber on the right side is going to the right side of the Splice Drawer. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved.
  • Page 44: Figure 9-4 Fiber Slack Straight In Front

    8. Rotate the cradle stack clockwise so that the fibers from the cradle stack and the fibers from the Splice Drawer cross. Figure 9-5 Rotate Cradle Stack Clockwise 9. Click the first cradle stack to the upper mounting location on the tray. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3 509.926.6000 — amphenol-ns.com...
  • Page 45: Figure 9-6 Click The Cradle Stack Into Place

    11. Secure fiber bundle together near the bend controls using supplied colored hook and loop. This can be used to identify the fibers that go to each cradle stack. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 46: Figure 9-8 Apply Colored Hook And Loop

    12. Route fiber bundle over the black bend controls and underneath tabs on the tray. Figure 9-9 Storing Slack Fiber 13. Repeat steps 6-11 with second cradle stack. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...
  • Page 47: Section Ten: Attaching The Frame Skin And Doors

    1. Install the side panels by resting the tabs onto the frame and push towards frame while depressing latches. Release latch when side panel is against splice frame in locations shown below. Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved.
  • Page 48: Figure 10-1 Side Panel Tabs

    2 Left and 2 right (not shown) Side Panel, 2 latches top and 1 in middle Cable Manager, 1 latch top and middle Figure 10-2 Installing Frame Covers Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3 509.926.6000 — amphenol-ns.com...
  • Page 49: Figure 10-3 Door Hinges On Cable Manager

    Install the Doors by sliding the hinges on the Door down onto the pre-installed hinges on the Vertical Cable Managers. Figure 10-3 Door Hinges on Cable Manager Amphenol Network Solutions PN 151657 InfinX Installation Guide All rights reserved. 10.18.2022 A3...