OKM Delta Ranger DR-A01 User Manual

Detector for treasure, gold and cavity hunt

Advertisement

Quick Links

USER MANUAL
TRANSPORTATION & STORAGE
SCOPE OF DELIVERY
ASSEMBLY
GETTING STARTED
OPERATIONS
MAINTENANCE
TROUBLESHOOTING
DISPOSAL
TECHNICAL SPECIFICATIONS
REPS & WARRANTIES
OKM
Delta Ranger
®
DETECTOR FOR TREASURE, GOLD AND CAVITY HUNT
MODEL: DR-A01
U.S. Edition | ENGLISH
© 2023 OKM GmbH. All Rights Reserved.
Version 1.0 | March 2023

Advertisement

Table of Contents
loading

Summary of Contents for OKM Delta Ranger DR-A01

  • Page 1 ASSEMBLY GETTING STARTED OPERATIONS MAINTENANCE TROUBLESHOOTING DISPOSAL TECHNICAL SPECIFICATIONS REPS & WARRANTIES Delta Ranger ® DETECTOR FOR TREASURE, GOLD AND CAVITY HUNT MODEL: DR-A01 U.S. Edition | ENGLISH © 2023 OKM GmbH. All Rights Reserved. Version 1.0 | March 2023...
  • Page 2: Table Of Contents

    4.7 CALIBRATE COMPASS ................18 10.3 LIMITATION OF LIABILITY .................59 No part of this document may be reproduced in any form (by printing, photocopying or other means) or processed, duplicated or circulated electronically without prior written approval of OKM GmbH. 4.8 SETTINGS .....................18 10.4 SERVICE &...
  • Page 3: Avoid Extreme Temperatures And Moisture

    1 TRANSPORTATION AND STORAGE 1.1 AVOID EXTREME TEMPERATURES AND MOISTURE Protect your detector and accessories by storing them in the Protector Case in a cool, dry place (50 to 75 °F | 10 to 25 °C). Unplug the probe from the Control Unit and power off the Control Unit before packing the device and its accessories into the case.
  • Page 4: Scope Of Delivery And Control Elements

     Headphones with charging cable   Long-Range Probe (L)   Thermo Probe (T)  VIII Ground Scan Probe (G)  Notebook with OKM Visualizer 3D Studio  Protector Case   VIII 6 / 62 7 / 62...
  • Page 5 VIII 2.5 PROBES The OKM Delta Ranger is equipped with various probes according to the acquired edition: Smartphone Mount – see 3.3 Attach Smartphone on page LED Lighting to illuminate dark areas.
  • Page 6 Socket. Note the correct position of the pins! noticable click sound. No additional tools are required to assemble the OKM Delta Ranger. 3.3 ATTACH SMARTPHONE Do not open the device and/or accessories. There are no end user serviceable parts inside.
  • Page 7 It can take up to 4 hours to fully charge the battery. The OKM Delta Ranger App is usually pre-installed on the included Android smartphone. Browse the Apps in your smartphone to make sure the required OKM App has not yet been installed.
  • Page 8 4.2.2 Activate OKM App If you have received a QR Code from OKM for Use the smartphone camera to scan the an automatic activation, select QR Code. QR Code that you received with the detector. Select Activate App from the Settings menu.
  • Page 9 This calibration is recommended before performing a new Press the trigger to power on the Control Unit. Power on the smartphone. Tap on the OKM measurement and every time you have changed the smartphone position on the Control Unit.
  • Page 10 ON and OFF. 4.8.2 Sound Activation 4.2.2 Activate OKM App on page 14 The App provides acoustic feedback for various functions. Tap on the switch to toggle between ON and OFF. To avoid attracting attention you may use Bluetooth headphones (see 4.5 Pair Wireless...
  • Page 11 4.8.5 App Theme 4.8.6 Length Unit NOTES Tap on the switch to toggle between Day Mode and Night Mode. Tap on the switch to toggle between Imperial and Metric. Day Mode is recommended in very bright environments. Night Mode is recommended in dark Imperial indicates all dimensions in feet (ft).
  • Page 12 5.3 OPERATING MODES The following operating modes are available in the OKM Delta Ranger App: 5.1 PACEMAKERS OKM Delta Ranger is a passive measuring instrument that does not emit magnetic waves. Bionic Stream 5.4 Bionic Stream on page 24 Clarify possible interferences with your medical doctor if you are wearing a pacemaker or similar medical device.
  • Page 13 5.4 BIONIC STREAM If contact to the electrodes is lost during calibrating or measuring, repeat the calibration by 5.4.3 Perform Triangulation Measurement tapping on Use the operating mode Bionic Stream to detect recently buried gold objects, long-time buried Triangulation (or Cross Bearing) uses two or more points simultaneously to fix a position. This procedure helps to determine a potential target spot more precisely and to verify detected target spots. gold as well as golden artifacts that are buried at long distances.
  • Page 14 5.5 IONIC STREAM 5.5.2 Measurement Screen 5.5.3 Perform Triangulation Measurement Use the operating mode Ionic Stream to detect gold objects that have been buried for a long time. Triangulation (or Cross Bearing) uses two or more points simultaneously to fix a position. This procedure helps to determine a potential target spot more precisely and to verify detected target spots. Make sure you have plugged in the Long-Range Probe (L).
  • Page 15 5.6 MAGNETOMETER 5.6.2 Measurement Screen 5.6.3 Perform Measurement 5.6.4 Interpret Measurement Use the operating mode Magnetometer to detect small metal objects like nails, screws and Magnetometer provides wires made of ferromagnetic materials such as iron, nickel and cobalt close to the surface. Re- •...
  • Page 16: Ground Scan

    5.7 3D GROUND SCAN Make sure you have connected the Ground Scan Probe (G). Use the operating mode 3D Ground Scan to get a detailed visualization of underground structures and potential target objects for further analysis in Visualizer 3D Studio. This operating mode allows vertical and horizontal (short-range) Learn more in the 3D Ground Scan Guide.
  • Page 17 5.7.2 Perform Default 3D Ground Scan The default parameters Field Length: Auto | Impulse Mode: Automatic | Scan Mode: Parallel are recommended for entry-level detector users and allow scanning in slightly sloping terrain. The scan file is opened in the File Explorer – Go to the starting point of the first scan line Walk to the end of the first scan line.
  • Page 18 5.7.3 Perform Zigzag 3D Ground Scan The parameters Field Length: Individual | Impulse Mode: Automatic | Scan Mode: Zigzag are recommended for advanced detector users and can be applied in flat terrain. The scan file is opened in the File Explorer – Go to the starting point of the first scan line Walk the first line at a constant speed.
  • Page 19 5.7.4 Perform Manual 3D Ground Scan The parameters Field Length: Auto | Impulse Mode: Manual | Scan Mode: Parallel are recommended for rough terrain. The scan file is opened in the File Explorer – Go to the starting point of the first scan line Press the trigger to start the measurement.
  • Page 20: Thermo Scan

    5.8 THERMO SCAN Make sure you have connected the Thermo Probe (T). Use the operating mode Thermo Scan to visualize hidden structures such as rooms, caves and tunnels based on noticeable temperature deviations of surfaces. These visualizations allow further analyses in Visualizer 3D Studio. This operating mode allows horizontal (short-range) and vertical probe orientation.
  • Page 21 5.8.2 Perform Zigzag Thermo Scan The parameters Field Length: Auto | Impulse Mode: Automatic | Scan Mode: Zigzag are recommended for fast measurements with horizontal probe orientation. 5.7.2 Perform Default 3D Ground Scan on page For measurements with vertical probe orientation refer to The scan file is opened in the File Explorer –...
  • Page 22 5.9 THERMO STREAM 5.9.1 Perform Measurement 5.9.2 Measurement Screen Use the operating mode Thermo Stream for initial explorations of unknown locations to detect structures such as hidden rooms, caves and tunnels behind walls and in the underground based on noticeable surface temperature deviations. Make sure you have connected the Thermo Probe (T).
  • Page 23: File Explorer

    Notebook and access the internal storage: For a more detailed analysis, transfer the scan files to a Windows notebook and open them in My PC > [Smartphone] > Internal shared storage > Documents > OKM > DeltaRanger 5.11 File Transfer on page BV6300Pro Visualizer 3D Studio –...
  • Page 24: Maintenance

    If the device is defective and it's a warranty case, refer to 10 REPS & WARRANTIES on page 58. If the device is defective but it is not a warranty case, you may use the service OKM Device Check, which includes: 1.
  • Page 25: Troubleshooting

    The Control Unit is not successfully connected to Tap on the red cross to retry establishing a connection. If this doesn't work, restart the the OKM App. App and the Control Unit: Hold the trigger for 3 seconds until the Control Unit turns off.
  • Page 26 3.2 Attach Probe on page 3.2 Attach Probe on page The operating mode won't start and I see the The required probe is not connected. Plug in the Long-Range Probe (L). See The operating mode won't start and I see the The required probe is not connected.
  • Page 27 NOTES 4.7 Calibrate The Compass Calibration failed. You moved too fast or too slowly. Retry calibration: Press the trigger and start rotating as slowly as described in Compass on page The probe was pivoted while calibrating. Retry calibration: Hold the detector horizontally during the complete calibration process. Press the trigger and start rotating.
  • Page 28: Disposal

    8 DISPOSAL Dispose the device or its components in accordance with local regulations. RECYCLE USED PRODUCTS! Reusing extends product life spans and contributes to the source reduction of raw materials. RECYCLE PROPERLY! Do not put devices with integrated batteries in the trash DISPOSAL or municipal recycling bins.
  • Page 29: Technical Specifications

    9 TECHNICAL SPECIFICATIONS 9.2 PROBES Manufacturer OKM GmbH 9.2.1 Long-Range Probe (L) Type Treasure Detector Length 7.7" | 195 mm Model DR-A01 Diameter 1.6" | 40 mm Weight 3.7 oz | 105 g The technical specifications are medial values. Slight variations are possible during operation.
  • Page 30: Reps & Warranties

    OKM, for a period of • opening of any technical component and/or accessory.
  • Page 31: Index

    11 INDEX Power on Triangulation 25 27 Probe connector 9 11 Trigger 8 16 Data transfer Label Probe connectors Day mode Language 16 18 19 Probe fitting 8 11 Download Laser Probe orientation 24 28 30 38 42 Update 13 18 47 Laser pointer 8 17 24 26 43 Probes...
  • Page 32 OKM DETECTORS HEADQUARTERS SUBSIDIARY SUBSIDIARY SUBSIDIARY OKM GmbH Julius-Zinkeisen-Str. 7 OKM Americas OKM Türkiye OKM Emirates FZE Charlotte 04600 Altenburg Antalya SAIF Zone, Sharjah Germany Turkey +49 162 419 2147 +49 3447 499 3000 info@okmdetectors.com www.okmdetectors.com...

Table of Contents