Wire the switch panel to the PAR-MAX rinse pump and toi-
let waste pump as per the following wiring diagram. The
brown lead from the control panel connects with the waste
pump orange (positive) motor lead. The yellow lead from
the control panel connects with the PAR-MAX rinse water
pump orange (positive) motor lead. The black motor lead
from each pump must be connected to battery negative.
Select a lo ca tion for the switch panel that is con ve nient to
the toilet user and will also allow access to run the wires
from the switch panel to both the toilet's waste pump motor
and the PAR-MAX pump as well as from the electrical
power source to the switch panel. To install the switch
panel, drill two 1-3/4" (45 mm) di am e ter holes (slight ly over-
lapping) through the se lect ed switch mounting surface per
the at tached tem plate. En sure the template is oriented cor-
rectly because it is not symmetrical. Also, drill four ap pro pri -
ate sized holes for the fas ten ers se lect ed to secure the
switch panel to its mounting surface.

ELECTRICAL SPECIFICATIONS

AMP
FUSE
VOLTAGE
DRAW
SIZE
12 Vdc
10
25
24 Vdc
5
15
* Length of run is total distance from power source to product and back to ground.
WIRE SIZE PER FEET OF RUN*
0'-10' (0 M-3 M)
10'-15' (3 M-4,6 M)
#16 (1,5 mm2)
#14 (2,5 mm2)
#16 (1,5 mm2)
#16 (1,5 mm2)

WIRING DIAGRAM

BROWN
To Positive
15'-25' (4,6 M-7,6 M)
25'-40' (7,6 M-12,2 M )
#12 (4 mm2)
#10 (6 mm2)
#16 (1,5 mm2)
#14 (2,5 mm2)
TEMPLATE
1-3/4" (45 mm) DIA
UP
1-3/4" (45 mm) DIA
YELLOW
To Waste Pump
Positive (Orange)
Motor Lead
BROWN
YELLOW
To PAR-MAX Pump
Positive (Orange)
Motor Lead
40'-60'(12,2 M-18,3 M)
#8 (10 mm2)
#12 (4 mm2)