Download Print this page

Electrical Specifications; Wiring Diagram - JABSCO 37055 Series Quick Start Manual

Advertisement

the electrical specifications chart. Secure all wires to a
solid surface approximately every eighteen inches (1/2M)
along their entire length of run.
Wire the switch panel to the solenoid valve/siphon breaker
and toilet pump assembly as per the following wiring
diagram. Connect the brown lead from the panel to the
waste pump positive (orange) lead. Connect the black
waste pump motor lead to battery negative. Connect the
yellow lead from the panel to a solenoid valve terminal.
Connect the remaining solenoid valve terminal to battery
negative. The solenoid valve is not polarity sensitive.
Select a location for the switch panel that is convenient
to the toilet user and will also allow access to run the
wires from the switch panel to both the toilet's motor and
the solenoid valve/siphon breaker as well as from the
electrical power source to the switch panel. To install the

ELECTRICAL SPECIFICATIONS

Amp
Voltage
Draw
12 Vdc
10
24 Vdc
5
* Length of run is total distance from power source to product and back to ground.
TEMPLATE
1-3/4" (45 mm) DIA
UP
1-3/4" (45 mm) DIA
PumpAgents.com - buy pumps and parts online
www.PumpAgents.com
Fuse
Size
0'-10'
10'-15'
25
#16
15
#16
switch panel, drill two 1-3/4" (45mm) diameter holes
(slightly over-lapping) through the selected switch
mounting surface per the attached template. Ensure the
template is oriented correctly because it is not
symmetrical. Also, drill four appropriate sized holes for
the fasteners selected to secure the switch panel to its
mounting surface.
SERVICE
The Jabsco Quiet-Flush Toilet does not require routine
maintenance other than occasional cleaning to maintain
a hygienic sanitary condition. Clean toilet with mild
nonabrasive
cleaners
Cleaners having high concentrations of aromatics such
as pine scented concentrated cleaners and strongly
scented degreaser concentrates can cause the pump's
seal to swell and may contribute to a premature seal leak.
Wire Size Per Feet Of Run*
15'-25'
#14
#12
#16
#16

WIRING DIAGRAM

BROWN
To Positive
without
strong
aromatics.
25'-40'
40'-60'
#10
#8
#14
#12
YELLOW
To Waste Pump
Positive (Orange)
Motor Lead
BROWN
YELLOW
To Solenoid
Valve/Siphon
Breaker

Advertisement

loading