BEFORE SERVICING OR TROUBLESHOOTING ENSURE THE PUMP IS DISCONNECTED
FROM MAINS SUPPLY.

Servicing:

• This Pump, like all mechanical equipment, requires periodic and regular maintenance.
• Reservoir and filter should be removed and cleaned with anti-bacterial solution, and
all tubing should be checked for leaks at maximum 3 month intervals during cooling season.
• Reservoir must be replaced flat & horizontal after removal for any reason.

Troubleshooting:

Fault: Pump runs all the time.
1. Is float present on sensor column?
2. Is float fitted with magnet facing upwards?
3. Is reservoir lid firmly seated on reservoir with float located around sensor column inside reservoir.
4. Is plug on sensor cable correctly and tightly inserted into socket on pump case and are terminals dry?
5. Is there sludge on reservoir bottom preventing float from resting on the bottom. This may occur if
pump has been in operation for some time without cleaning.
Clean reservoir and float with anti bacterial solution.
6. Does evaporator produce more condensate water than pump can handle. If so,
pump is too small and must be replaced with larger unit or different type.
NOTE:
AFTER INSTALLATION AND DURING OPERATION, PRESENCE OF AIR IN PIPE BETWEEN
RESERVOIR AND PUMP INDICATES A BACKFLOW PROBLEM.
REFER TO GUIDELINES ON PAGE 3 TO REMEDY THIS.
PUMP WILL ONLY SWITCH OFF WHEN FLOAT IS RESTING FLAT ON BOTTOM OF RESERVOIR.
Fault: Pump stops and starts and makes a loud noise.
1. The water is backflowing into the pump. Follow guidelines on page 3 to prevent backflow.
Fault: Pump runs but does not pump any water.
1. Check for air leaks in the pipe between reservoir and pump. Use cable ties to to ensure an airtight seal.
2. Check that reservoir and inlet tube are free of sludge and debris.
Fault: Pump doesn't operate.
1. Is voltage correct?
2. Check fuse for continuity.
3. Is pump correctly wired?
4. Is power reaching pump?
5. Is pump very hot? A thermal cut-out may have been activated to protect pump.
This will automatically reset once pump has cooled down.
WARNING:
1. SIZE PUMP TO HANDLE MAXIMUM CONDENSATE FLOW UNDER WORST CASE CONDITIONS.
2. CHECK PUMP FOR CORRECT VOLTAGE BEFORE STARTING INSTALLATION.
3. INSTALL, PIPE AND WIRE STRICTLY IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS.
4. DO NOT OPERATE PUMP WITHOUT FILTER.
5. DO NOT RUN PUMP DRY, SERIOUS DAMAGE WILL OCCUR AND INVALIDATE WARRANTY.
6. INSPECT PUMP REGULARLY AND CLEAN RESERVOIR AND FILTER. FLOATSWITCH MUST OPERATE FREELY
AT ALL TIMES.
7. DO NOT LEAVE SITE WITHOUT TESTING PUMP FOR CORRECT OPERATION AFTER INSTALLATION AND
MAINTENANCE.
7
Thank you for buying your new Mini Orange Pump.
This manual provides complete instructions for the correct installation and maintenance of pump which should
be carefully followed. Please record following information for future reference:
Serial number:
Date installed:
Imported and Distributed by:
3 Kellogg Court, Unit 10, Edison, NJ 08817 Tel: 732-248-8066 Fax: 732-248-8068 email: info@eztrap.com website: www.eztrap.com
Product Warranty
The manufacturer disclaims all implied and express warranties, including the implied warranty of merchantability and the implied warranty of fitness for a particular purpose, except as follows:
The EZ-Trap condensate product purchased by you concurrently is unconditionally warranteed to be free from defects in material and workmanship under normal use for a period of one year from date
of purchase, providing it is installed and operated strictly in accordance with the manufacturer's installation instructions. If the product is found to be defect or otherwise fails in normal use, you may
return it for replacement. All freight charges for the return of the product shall be borne by you. The manufacturer will pay outgoing freight charges for the replacement product. Defective product
returned to the factory prepaid will be repaired or replaced free of charge. Replacement product will, to the extent such product is then available in the manufacturer's inventory, be of a similar type of
color and kind. Manufacturer retains the right to substitute product if the replacement product does not conform in terms of color, type and specifications to the original product if no longer available.
This warranty does not cover replacement labor or any cost, claim or incident to any defect nor does it cover any consequential damages. The sole liability of the manufacturer under this warranty is
limited to the replacement of defective product. Product damaged by improper use, accident, neglect, alteration, abuse or improper installation is excluded from this warranty.
Part No. 1810
Manufactured by: Aspen Pumps Apex Way Hailsham East Sussex BN27 3WA United Kingdom website: www.aspenpumps.com
mini orange pump
INSTALLATION & MAINTENANCE MANUAL
FOR MODELS ASP-MO115 & ASP-MO230
false ceiling where possible, inside casing
of minisplit evaporator unit where space
Operating Voltage:
Location of pump:
®
Designed for installation above a
permits or inside lineset cover
Quick and easy to install
The Mini Orange will quietly and
reliably pump condensate water
to a maximum height of 26 feet
2 reservoir options supplied
for installation flexibility

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the mini orange and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Aspen Pumps mini orange

  • Page 1 Product damaged by improper use, accident, neglect, alteration, abuse or improper installation is excluded from this warranty. Part No. 1810 Manufactured by: Aspen Pumps Apex Way Hailsham East Sussex BN27 3WA United Kingdom website: www.aspenpumps.com...
  • Page 2 • Power supply 115V or 230 V AC 60Hz Capacity 3.7 GPH @ zero head 0.8 GPH @26ft head • CAUTION: The Mini Orange Pump has been evaluated for use with water only. • • Volt-free Alarm wires, N/O N/C.
  • Page 3 Backflow Prevention: guidelines Installation: reservoir • Ensure that discharge tube ends above water level in evaporator tray. Select correct reservoir type A inline or B panmount FALSE CEILING EVAPORATOR COIL END OF DISCHARGE TUBE TOP OF BREATHER TUBE CONDENSATE DRAIN TRAY WATER LEVEL IN EVAPORATOR TRAY •...
  • Page 4 Installation - Reservoir: Installation - Drain Hose and wiring: Secure reservoir A and B horizontally. If using inline reservoir A , connect inlet Plug reservoir sensor cable into pump firmly to drain pipe from evaporator using orange connector tube. Use self adhesive unit.
  • Page 5 La única responsabilidad del fabricante con esta garantía se limita al cambio del producto defectuoso. El producto dañado por uso indebido, accidente, negligencia, alteración, maltrato o instalación incorrecta queda excluido de esta garantía. Fabricado por: Aspen Pumps Apex Way Hailsham East Sussex BN27 3WA Reino Unido sitio web: www.aspenpumps.com...
  • Page 6 Capacidad 3.7 GPH @ cero carga 0.8 GPH @26 pies carga • Fuente de alimentación 115V o 230 V CA 60Hz • PRECAUCIÓN: La bomba Mini Orange ha sido evaluada para utilizarse solamente con agua. Carga máxima: 26 pies • •...
  • Page 7 Prevención del flujo inverso: pautas Instalación: tanque • Asegúrese de que el tubo de descarga termine sobre el nivel de agua en la bandeja del evaporador. Seleccione el tipo de tanque correcto en línea A o B montaje en recipiente TECHO FALSO SERPENTÍN DEL EVAPORADOR EXTREMO DEL TUBO DE DESCARGA...
  • Page 8 Instalación - Tanque: Instalación - Manguera de drenaje y cableado: Asegure el tanque A y B horizontalmente. Si usa el tanque en línea A , conecte la entrada Enchufe el cable de sensor del tanque en la firmemente a la tubería de drenaje desde el evaporador usando el tubo conector anaranjado. unidad de la bomba.

This manual is also suitable for:

Asp-mo115Asp-mo230

Table of Contents