Platforms TESLA VISION MRI Bore Projection System Part Number: UX-PS-K-001 & UX-PS-K-002 User Manual English UX Platforms, Inc. Technical Support Phone: (858) 519-7304 Email: support@uxplatforms.com UMN-01-Rev C...
Caution: Use of accessories, cables, and other equipment not specified or provided by UX Platforms, Inc. could result in increased electromagnetic emissions or decreased electromagnetic immunity of the equipment and result in improper operation. Caution: Use of its equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation.
WARNING The projector unit has a minimal amount of ferrous material and is considered MR Conditional. DO NOT introduce the projector unit to the opening of the MRI bore. Serious injury or death may occur to patients or the individual handling the equipment, due to the high strength of the MRI magnetic field.
REPORTING INCIDENTS Contact the manufacturer immediately to report an incident and/or injury to a patient, operator or maintenance employee that occurred while using the Tesla Vision system and do not operate the equipment until an investigation is conducted. EMERGENCY PROCEDURE In the unlikely event that either the Tesla Vision system or any component of the system creates smoke, sparks, or if the patient requires emergency assistance: - Stop the scan if one is in progress.
ITEM CHECK LIST Below is a list of the major components the system is comprised of. Their description and MRI safety information are also provided. Tesla Projector Control Units Rolling Mount Assembly This component displays video These components allow Positions the projector safely onto the surface of the MRI technologists to choose behind the MRI bore.
CONTENTS Safety & indications for use Device description ....................2 Indications for use ....................2 Cleaning the device ....................2 Warnings & Cautions ....................3 MRI Safety information .................... 4 Components & user guides Item check list ......................5 Contents ........................6 Quick start guide &...
QUICK START GUIDE & SYSTEM OPERATION Powering on/off projector To power on/off the projector press the circular power button circled in red. - A blue LED located above the button will blink once showing the command was sent. - Look inside the MRI bore to see if the projector is ON or OFF.
COMPONENT DIAGRAM Video Control Unit & Application Below is a diagram of the control unit that allows the technologist to choose video and power on/off the projector system. The application interface below is currently set to whole bore. Reference page 14 for the cinema interface. Power Button ON/OFF Cinema Video Current Live Feed Video...
Page 9
COMPONENT DIAGRAM Rolling Mount Assembly Below is a diagram of the rolling mount assembly which holds the projector into place. It will be position behind the MRI bore and to the side of the patient table. Before playing video for the patient make sure it is fully locked into the floor mount bracket.
Page 10
COMPONENT DIAGRAM WARNING: Only components labeled MR Safe or Component Locations MR Conditional are allowed in the MRI Room. Below is a diagram of each component located within and outside the MRI room. Use the table on page 11 for reference. Control Room Computer Room ZONE 3...
Page 11
COMPONENT DIAGRAM Component Locations Below is the reference table for components listed 1-8 inside and outside the MRI room. Component # Location Component Description Control Room Control Units: The control unit is placed ZONE 3 on the technologists desk. Consisting parts: Remote power switch, tablet, tablet mount Computer Room Power Block: The remote power block...
INSTRUCTIONS Moving/Storing the Projector System Unlocking the rolling mount CAUTION: The projector unit must be powered OFF before moving it throughout the MRI room. If powered ON while moving it through the Hold pillar here magnetic field you will induce currents and possibly damage the device.
Page 13
INSTRUCTIONS Moving/Storing the Projector System Cable management When moving the system to another location, be aware of the RF Shielded cable locations. Rolling over it or stacking objects on it may cause damage and render the system inoperable. BNC Cable Storage location When storing the system away from its bracket, ensure W a l l...
Page 14
INSTRUCTIONS Changing Full Bore Video to Cinema Video Setting 1: Whole bore video When displaying whole bore video the “cinema lens” must be positioned up until its resting on top of the projector housing. This will allow the projector to display a larger image onto the entire surface of the MRI bore.
Page 15
INSTRUCTIONS Mirror Arch Display Caution: Only lift the Mirror Arch display with two hands holding both support legs. Note: The Mirror Arch display only works for head first scans, not feet first. Positioning the Mirror Arch display Position the patient on the MRI bed 2”...
Please read and carefully follow the troubleshooting suggestions below if you are having issues with the system. NOTE: If any component of the system appears to be damaged, please contact UX Platforms. You may find the contact information on the last page of this manual.
SPECIFICATIONS The electrical components of this device are not user serviceable. Any con- tact with the wiring or other electrical components by untrained persons may result in serious injury or death. Component Weight Tesla Projector 3.5 lbs Rolling Mount Assembly 20 lbs Wi-Fi / Power Box 7 lbs...
Page 18
SPECIFICATIONS Note: At 80 MHz and 800 MHz, the higher frequency range applies. Note: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broad- cast cannot be predicted theoretically with accuracy.