Chapter 3
Understanding Erpcd
at_connect_time
at_nve_filter
Using Remote Access Concentrator Server Tools for Windows NT
3-14
The at_connect_time attribute specifies the number of minutes that an
ARA connection can remain open. To use this attribute:
1.
From the Bay Networks program group window, double-
click on the appropriate icon to open the acp_userinfo file.
The acp_userinfo file opens in the Notepad editor.
2.
Find the area of the file where entry information resides and
type
at_connect_time
user john
at_connect_time 12
end
The above example limits the session to twelve minutes.
The at_nve_filter attribute allows you to include or exclude users from
specific objects, network numbers, subzones, and zones. Specify one
at_nve_filter attribute for each user in a profile. To use this attribute:
1.
From the Bay Networks program group window, double-
click on the appropriate icon to open the acp_userinfo file.
The acp_userinfo file opens in the Notepad editor.
2.
Find the area of the file where entry information resides and
type
at_nve_filter
3.
Type
include
4.
Enter an object name followed by a colon (:).
5.
Enter a network number or subzone name followed by @.
6.
Enter a zone name.
followed by the number of minutes.
.
or
.
exclude