WLAN 2300 Series Outdoor Solution with AP Mounted in NEMA Enclosure 61
Grounding principles
To connect the Surge Protector to ground, use the shortest and most direct run possible with #8 solid copper
wire (or equivalent).
Refer to your local electric code standards for correct installation.
Applying coax seal tape
For applying Coax seal tape refer:
See "Coax cable seal installation" page 52
Installation of AP 2330A/2330B
In this section you will find instructions on installing the AP 2330A/2330B in an outdoor mounted enclosure.
Installation of the NEMA Enclosure
1
Remove the NEMA Enclosure from the ODS kit and place it on a flat surface near the installation
location. The following figure shows the enclosure connections from left to right: ground lug, Ethernet
Gland, and two external antenna connectors.
Figure 12.
NEMA Enclosure
2
Open the enclosure cover by pushing the latches down on the side and lifting the cover up.
Nortel WLAN 2300 Series Outdoor Solution Guide