please replace it.
b. 电源异常,根本没有外电进入机器控制电路,检查电源线的通电状态.
Please check the power line and check if the power line connecting with machine well.
c. 如上面两项都排除,没有故障,则机器线路板损杯,请联系供货厂商售后服务.
Please find electric engineer to check the circuit board, If you confirm the board broken, Please contact with our
company.
2 机器无动作 No action
a.
检察机器面板显示有无异常,如完全无显示,请参照第一项的处理方法.
Please confirm the indicator display ok.
b.
检察进气气压表有无压力,机器是否处于通气状态.
Please check the pressure meter , confirm the air connecting well
c.
感应开关是否损坏及是否感应到位:最简单的方法,面板上有 7 个小灯,每个小灯代表不同的位置状态,具体的
显示如下:
其它的 4 个灯没有具体的含义,将机器的进气气源关闭,将印头推到右边,看面板上右位感应灯是否亮起,依次
类推,如果三个位置到位,有灯没亮,则说明该位置的感应开关损坏或者没感应,请现场具体判断,如果感应开关都
显示没故障,有可能电路板损坏,请联系厂家处理。
There are three sensor switches , Please confirm the three switches well.
Shut off the air switching, Mode the printing head to Right side, Check the indicator of Right side sensor LED.
Then moving the printing head to left side, check the indicator of left side sensor LED.
If three indicator keep good, Perhaps circuit board broken, Please contact with our sales person.
d.
检察电磁阀蕊和线圈是否有问题,处理方法:断开电源,不断气压按电磁阀上的小蓝色按钮,如不动作则阀蕊坏,
更换同型号的电磁阀测量线圈阻值是否在 50 欧姆左右,若有问题则更换同型号的线圈。
Check the Solenoid valve:
Shut of the power supply, Keep pressing the blue button on solenoid valve, If the solenoid valve no action, Please
replace it. Please measure the Resistivity of coil about 50 OHM.
3.机器动作不正常 Abnormal run action
机器运行中,没完成印刷循环,在一半突然回位,时不时出现此类情况,并不是每次都是这样,有两种情况:
a,线路板程序错乱,
b,外部电磁干扰,移动机器位置到车间的另一位置测试效果。
东莞市高宝印刷机械科技有限公司
Dongguan KC Printing Machine Limited
Website: Http://www.dg-padprinter.com
Online contact
Skype: yingsuhuakelven QQ: 726986799
Email:
cjscbsf@126.com