6. Alarms

6.4 Anomaly load alarm

This alarm will only trigger if pump is being powered from the battery during a mains power cut.
If the current being drawn by the pump is greater than the inverter's capacity, the inverter will automatically stop powering the
pump. After 30 seconds, the system will attempt to power the pump again. After a 5th failed attempt, the system will stop trying
to power the pump and trigger the anomalous load alarm. It is switched by relay K6.
After the fifth attempt the display will read "ANOMALY LOAD".
This alarm state does not automatically reset. To clear the alarm, press the RESET button.