Northern Telecom Meridian SL-1 Reference Manual page 13

2-mbs/ remote peripheral equipment cabinet maintenance/equipment replacement
Hide thumbs Also See for Meridian SL-1:
Table of Contents

Advertisement

Chart 2-3
PE2, PE3, PE4 or PE5 breaker trips
St ep
Ac ti on
1
Reset breaker.
2
Check for extinguished LED
on QPC706 pack associated
with tripped breaker and
replace pack. Reset breaker.
3
Unseat all circuit packs on the
shelf except the QPC706
pack. Reset breaker.
4
Insert circuits one-at-a-time
until breaker trips.
2-Mb/s Remote Peripheral Equipment
Fault detection and locating 2-9
Ver if i cat io n
If breaker does not trip, fault is
cleared.
If breaker does not trip, fault is
cleared.
If breaker trips, replace power
cabling to shelf at rear of cabinet.
If breaker still trips when reset,
replace the QUX20 unit.
Last circuit pack inserted is
defective. Replace.
Appendix 1 to 553-2741-500

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Meridian SL-1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Qca146Sl-1

Table of Contents